Code
Message/Explanation
1008
Lss too low.
1009
Invalid parameter.
1010
Hardware error.
1011
I/O error.
1012
Too many fi les opened.
1013
Device not found.
1014
File not found.
1015
File is read-only.
1016
Illegal argument.
1017
Result too large.
1018
Bad fi le descriptor.
1019
Invalid font.
1020
Invalid image.
1021
Too large argument for MAG.
1022
Head lifted.
1023
Incomplete label.
1024
File too large.
1025
File does not exist.
1026
Label pending.
1027
Out of transfer ribbon.
1028
Media type is not selected.
1029
Printhead voltage too high.
1030
Character is missing in chosen font.
1031
Next label not found.
1032
File name too long.
1033
Too many fi les are open.
1034
Not a directory.
1035
File pointer is not inside the fi le.
1036
Subscript out of range.
1037
No acknowledge received within specifi ed
timeout.
1038
Communication checksum error.
1039
Not mounted.
1040
Unknown fi le operating system.
1041
Error in fos structure.
1042
Internal error in mcs.
1043
Timer table full.
1044
Low battery in memory card.
1045
Media was removed.
1046
Memory checksum error.
1047
Interrupted system call.
1051
Dot resistance measure out of limits.
1052
Error in printhead.
1053
Unable to complete a dot measurement.
Intermec Direct Protocol v7.80 Programmer's Reference Manual
Chapter 11 — Error Messages
Code
Message/Explanation
1054
Error when trying to write to device.
1055
Error when trying to read from device.
1056
O_BIT open error.
1057
File exists.
1058
Transfer ribbon fi tted.
1059
Cutter does not respond.
1060
DC motor to ribbon save did not start/stop.
1061
Wrong type of media.
1062
Not Allowed.
1081
Timer expired.
1082
Unsupported protocol.
1083
Ribbon Low
1101
Illegal character in bar code.
1102
Illegal bar code font.
1103
Too many characters in bar code.
1104
Bar code too large.
1105
Bar code parameter error.
1106
Wrong number of characters.
1107
Illegal bar code size.
1108
Number or rows out of range.
1109
Number of columns out of range.
1201
Insuffi cient font data loaded.
1202
Transformation matrix out of range.
1203
Font format error.
1204
Specifi cations not compatible with output
module.
1205
Intelligent transform not supported.
1206
Unsupported output mode requested.
1207
Extended font not supported.
1208
Font specifi cations not set.
1209
Track kerning data not available.
1210
Pair kerning data not available.
1211
Other Speedo error.
1212
No bitmap or outline device.
1213
Speedo error six.
1214
Squeeze or clip not supported.
1215
Character data not available.
1216
Unknown font.
1217
Font format is not supported.
1218
Correct mapping table is not found.
1219
Font is in the wrong direction.
1220
Error in external map table.
1221
Map table was not found.
1222
Double byte map table is missing.
121