Nortel IVR 2.5/S Manual page 35

Aculab-based e1 cas/isdn pri
Table of Contents

Advertisement

B-4 Card configurations
Standard 1.0
July 1997
Notes:
1
The ACL-60 is always a clock master on the PEB.
2
Set the appropriate jumpers to ground the shield for each BNC connector
in use.
BNC Connector
Port 2 TX2
Port 2 RX2
Port 1 TX1
Port 1 RX1
3
Each PEB connection requires one D/320-SC card.
4
You must terminate the PEB at both ends to ensure proper electrical
characteristics. The ACL-60 has built-in PEB terminators, so you must
install the ACL-60 at one end of the PEB cable. You must remove all
PEB terminators from the resource cards (TTS, VR, Fax) on the PEB.
5
The ACL-60 uses shared memory range E0000 to EFFFF.
6
Only one ACL-60 card per system is allowed.
Grounding Jumper
JP34 - ON
JP33 - ON
JP32 - ON
JP31 - ON