Fujitsu PRIMERGY RX1330 M4 Upgrade And Maintenance Manual page 79

Hide thumbs Also See for PRIMERGY RX1330 M4:
Table of Contents

Advertisement

▶ Enter the command below, followed by [ENTER]:
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
▶ Log in as root.
▶ Enter the commands below, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
▶ Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using Infrastructure Manager
The status of server (node) which failed CPU is installed becomes error.
RX1330 M4
Upgrade and Maintenance Manual
Basic software procedures
79