Dip Switch Settings - YASKAWA SigmaLogic7 Compact Hardware Manual

Table of Contents

Advertisement

2.2 DIP Switch Settings

Switch
Name
Setting
ON
1
STOP
OFF
ON
2
SUP
OFF
ON
3
INIT
OFF
ON
4
E-INIT
OFF
Operating Mode
User program execution
inhibited
Normal operation
Firmware programming
mode
Normal operation
Configuration bypass
mode
Normal operation
Normal operation
Rotary switches ignored
2 Specifications and Settings
1
2
DIP Switches
3
4
Rotary
Switches
(used to
set IP
address)
Rotary Switch 1
Setting for
Normal
Operation
OFF
Inhibits user program execution
Enables servo controller firmware
programming. This mode can also be
OFF
performed via web UI without changing
the DIP switch.
Set to ON to bypass the stored
configuration (e.g. in case of a
OFF
configuration problem that prevents
servo controller startup)
Rotary switches used to set IP address
OFF
IP address is set from configuration
settings in servo controller
2.1.2 400 V Specifications
Rotary Switch 0
Details
13