2 Specifications and Settings
2.1.2 400 V Specifications
Item
Displays/Indicators
Ethernet IP Address Setting Switches
Analog Monitor (CN5)
Dynamic Brake (DB)
Regenerative Processing
Overtravel (OT) Prevention
Protective Functions
Utility Functions
Inputs
Output
Safety
Functions
Applicable
Standards
* 1. If you combine a -7-Series SERVOPACK with a -V-Series Option Module, the surrounding air tempera-
ture specification of the -V-Series SERVOPACKs must be used, i.e., 0°C to 55°C. Also, the applicable
surrounding range cannot be increased by derating.
* 2. The coefficient of speed fluctuation for load fluctuation is defined as follows:
Coefficient of speed fluctuation = No-load motor speed - Total-load motor speed
* 3. Always perform risk assessment for the system and confirm that the safety requirements are met.
12
CHARGE, PWR, RUN, ERR, and L/A (A and B) indicators, and
one-digit seven-segment display
Used to configure IP address
Number of points: 2
Output voltage range: ±10 VDC (effective linearity range: ±8 V)
Resolution: 16 bits
Accuracy: ±20 mV (Typ)
Maximum output current: ±10 mA
Settling time (±1%): 1.2 ms (Typ)
Activated when a servo alarm or overtravel (OT) occurs, or
when the power supply to the main circuit or servo is OFF.
Built-in
Refer to the catalog for details.
Stopping with dynamic brake, deceleration to a stop, or coast-
ing to a stop for the P-OT (Forward Drive Prohibit) or N-OT
(Reverse Drive Prohibit) signal
Overcurrent, overvoltage, low voltage, overload, regeneration
error, etc.
Gain adjustment, alarm history, jogging, origin search, etc.
/HWBB1 and /HWBB2: Base block signals for Power Modules
EDM1: Monitors the status of built-in safety circuit (fixed out-
put).
ISO13849-1 PLe (category 3), IEC61508 SIL3
*3
Specification
Rated motor speed
×
100%