 D-3.1 Faults - Causes - Solutions
THE
WORK
PLATFORM
CONTROLS DO NOT FUNCTION
WARNING LAMP "B" (fig. C10)
DOES NOT SWITCH ON
ALARM SIGNALLED BY THE
OVERLOAD WARNING SYSTEM
38
Page
• Plug is not connected
• Robot locking sensor wrongly
positioned
• Controls not switched from handler
to platform
• Stabilisers are up
• Key-switch A set to "Cab controls"
• Platform overload
• Ensure the power plug on the boom
has been properly plugged in (see
C-1)
• Adjust the sensor distance (see
section Maintenance - Adjusting
the sensor distance in the opera-
tor's handbook of the handler)
• Try to switch again the controls from
handler to platform (see C-6.1)
• Lower the stabilisers
• Set the switch to "Platform controls"
• Remove any load in excess from the
platform. For the payload limits, read
chapter C-6.