Your server has an error due to a Blocked Logical Drive.
Explanation: One or more logical drives are blocked. A blocked logical drive cannot be accessed. See "Logical
drive state descriptions" on page 38 for additional information.
Action: Press F4 to unblock the logical drive, or press F5 to continue without unblocking.

ServeRAID POST messages

The following numeric POST messages appear in hexadecimal format.
1xxx to 7xxx
Explanation: The POST detected an internal error.
Action: Have the system serviced.
2601 to 260B
Explanation: The POST detected an error with the ServeRAID subsystem.
Action: Have the system serviced.
2610
Explanation: The POST detected an error with the ServeRAID controller hardware.
Action: Have the system serviced.
2620
Explanation: The POST detected that a ServeRAID configuration or hard disk error occurred.
Action: Start the IBM ServeRAID Support CD and view the existing device and configuration information for your
ServeRAID subsystem. If you cannot locate and correct the configuration problem or the failing device, or if the
problem persists, have the system serviced.
8xxx to Bxxx
Explanation: The POST detected an error with the SCSI interface.
Action: Verify that the SCSI cables are correctly connected and the SCSI termination is set properly for each
installed SCSI device.
If you cannot locate and correct the SCSI problem, or if the problem persists, have the system serviced.