No.
Bobbin winding speed can be set.
Motion method of wiper can be selected.
Unit of sewing shape size change can be selected.
Function for IP-400 only
Thread tension output time
when setting thread tension can be set.
Bend position of thread clamp is selected.
Thread clamp and thread clamp position selection
Thread breakage detection selection
Number of invalid stitches at the start
of sewing of thread breakage detection
Number of invalid stitches during sewing
of thread breakage detection
Item
0 : Invalid
1 : Magnet type wiper
0 : %input
1 : Actual size input
0 : 0 : S type
1 : H type thin thread (#50 to #8)
2 : H type intermediate
3 : H type thick thread (#5 to #2)
0 : Standard (Front position)
1 : Rear position
0 : Thread breakage detection invalid
1 : Thread breakage detection valid
– 101 –
Setting range
Edit unit
800 to 2000
100rpm
---
---
---
---
0 to 20
1
---
---
---
---
---
---
0 to 15 stitches
1 stitch
1 stitch
0 to 15 stitches