JUKI AMS-210E-1306 Instruction Manual page 103

Table of Contents

Advertisement

No.
Operation panel key lock mode (CP-20 only)
0 : Normal
1 : X enlarging /
Y enlarging / speed Item skip
Counter motion selection (CP-20 only)
0 : Sewing UP counter
1 : Bobbin thread DOWN counter
Height of eight of presser at the time
of 2 step scrolling
Buzzer sound can be prohibited.
Number of stitches
of thread clamp release is set.
Clamping timing
of thread clamp can be delayed.
Thread clamp control can be prohibited.
Feed motion timing is selected.
Set the timing in "–" direction when
stitch is not well-tightened.
State of the presser after end of sewing is selected.
Item
0 : Without buzzer sound
1 : Panel operating sound
2 : Panel operating sound + error
0 : Normal
1 : Prohibited
0 : Presser goes up after moving at start of
sewing.
1 : Presser goes up immediately afterend of
sewing.
2 : Presser goes up by pedal operation after
moving at start of sewing.
– 99 –
Setting range
Edit unit
---
---
---
---
1
50 to 90
---
---
1 to 7
1
1
– 10 to 0
---
---
– 8 to 16
1
---
---

Advertisement