Examples with G.703 Gateway

About G.703 Ports
G.703 Ports:
To address the G.703 ports in a dialling rule
the physical G.703 ports have a numeric
representation with two digits for each the
interface number and the module number as
well as a one digit representation for the call
number.
Make sure that this string always contains 5
digits.
Range will therefore be 01011 to 06085 for
corresponding G.703 cards/modules in slot 1
port 1 call 1 to slot 6 port 8 call 5.
Example:
Slot 1 Port 1 Call 1: 01011
Slot 1 Port 1 Call 2: 01012
Slot 1 Port 1 Call 3: 01013
....
Slot 1 Port 8 Call 3: 01083
Slot 1 Port 8 Call 4: 01084
Slot 1 Port 8 Call 5: 01085
Slot 6 Port 1 Call 1: 06011
Slot 6 Port 1 Call 2: 06012
Slot 6 Port 1 Call 3: 06013
....
Slot 6 Port 8 Call 3: 06083
Slot 6 Port 8 Call 4: 06084
Slot 6 Port 8 Call 5: 06085
For further information about how the
video system endpoint supports TCS-4
please see the MXP Administrator's
Guide on http://www.tandberg.com.
Table of
Main
Introduction
Contents
D 13373.08
NOVEMBER 2007
Example 1: DID
Example with DID:
You would like to have a DID number from
H.323 to G.703.
Add Dialling Rule
Type
DID
1.
Set
to
Select
Bandwidth
2.
Set
Number of Significant Digits
to empty
3.
0
or to
(zero)
From Network Type
H.323
4.
Set
to
From Prefix
9
5.
Set
to
To Network Type
G.703
6.
Set
to
To Prefix
7.
Leave
empty
To call G.703 call 1 on port 1 on module card
1 would require you to dial 901011 from the
H.323 endpoint.
The J3 software and above supports
H.323 to G.703 Gateway.
Quick
Using
Installation
Setup
the MPS
Example 2: DID
Example with DID:
You would like to have a DID number from
H.323 to a specific G.703 card.
Add Dialling Rule
Type
DID
1.
Set
to
Select
Bandwidth
2.
Set
Number of Significant Digits
3.
0
or to
(zero)
From Network Type
H.323
4.
Set
to
From Prefix
9
5.
Set
to
To Network Type
G.703
6.
Set
to
To Prefix
01
7.
Set
to
To call G.703 call 3 on port 2 on module card
1 would require you to dial 9023 from the
H.323 endpoint.
System
System
Status
Configuration
117
Example 3: DID
Example with DID:
You would like to have a DID number from
H.323 to a specific G.703 call.
Add Dialling Rule
Type
DID
1.
Set
to
Bandwidth
2.
Select
to empty
Number of Significant Digits
3.
Set
or to
0
(zero)
4.
Set
From Network Type
From Prefix
9
5.
Set
to
To Network Type
6.
Set
To Prefix
01062
7.
Set
to
To call G.703 call 2 on port 6 on module card
1 would require you to dial 9 from the H.323
endpoint.
Gateway
MCU
Technical
Configuration
Configuration
Descriptions
TANDBERG
MPS
ADMINISTRATOR GUIDE
to empty
to
H.323
G.703
to
Appendices
MPS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mps 200Mps 800Media processing system mps 800

Table of Contents