Serial V.35 Board Interfaces - TANDBERG Media Processing System MPS 200 Administrator's Manual

Tandberg media processing system administrator guide
Table of Contents

Advertisement

Serial V.35 Board

Serial V.35 Board Interfaces

Slot (1 to n)
Select Slot
1
to
6
to configure the Serial V.35 Board(s). The
picture shows that Serial V.35 Boards installed on Slot 4.
Indicates ok
Indicates an error
Internal Bandwidth
Sets the clock rate the MPS will provide to all ports when
set to Internal for clocking. Can be set to a clock rate from
64kbps up to 1920 kbps.
Call Control, port 1-32
Dial Manual:
Select Dial Manual when no handshake
signals are available or when using RS366 with other IMUX
and the external equipment requires a constantly connected
line. (Default: Dial Manual)
RS366 ADTRAN:
Select RS366 ADTRAN only when con-
nected to an ADTRAN ISU 512.
The ADTRAN ISU 512 offers extra usability when dialling
RS366 via an ADTRAN ISU 512 IMUX.
This dialling scheme will map the call type and bandwidth
selection to ADTRAN ISU 512 specific suffixes to the
dialled number.
Clocking, port 1-32
Dual:
When using RS449, RS530, and V.35 the external
equipment provides two clock signals, one for transmit and
one for receive. The difference between RS449, RS530 and
V.35 is the cable only (Default: Dual).
Single:
Used when the external equipment provides one com-
mon clock signal, X.21, for both transmit and receive.
DTR Puls, port 1-32
On:
Set to On if the port is used for incoming Gateway calls.
Off:
Set to Off if the port is not used for incoming Gateway
calls. (Default: Off)
Table of
Main
Introduction
Contents
D 13373.08
NOVEMBER 2007
Network Configuration
Save
Gateway Bandwidth, port 1-32
The incoming connection Bandwidth may be set to:
64 kbps, 128 kbps, 192 kbps, 256 kbps, 320 kbps, 384 kbps, 512 kbps, 768
kbps, 1152 kbps, 1472 kbps, 1536 kbps and 1920 kbps (Default: 384 kbps).
This is for incoming Gateway calls and has no effect when used for MCU calls.
Quick
Using
Installation
Setup
the MPS
- Press the Save button to save changes.
System
System
Configuration
Status
100
Restrict, port 1-32
On:
When set to On, call rates are increment-
ed in steps of 56 kbps.
Off:
When set to Off, call rates are increment-
ed in steps of 64 kbps. (Default: Off)
Gateway
MCU
Technical
Configuration
Configuration
Descriptions
TANDBERG
MPS
ADMINISTRATOR GUIDE
Appendices
MPS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mps 200Mps 800Media processing system mps 800

Table of Contents