MPS 200
MPS 800
Administrator
Guide
Software version J4.1
D13373.08
November 2007
Table of
Main
Introduction
Contents
D 13373.08
NOVEMBER 2007
Join up to 40/160 video and 32/48 audio sites
in one or more conferences
19" rack-mountable chassis with LCD in front
and CompactPCI backplane
Wide range of network and protocol support: SIP,
IP, ISDN and V.35
Supports H.264 with Continuous Presence and
Voice Switching
Modular and expandable with multiple media pro-
cessing boards and network interface boards
Bandwidth: from 56 kbps–2 Mbps
Supports Simultaneous display of presenter and
presentations, Dual Video Stream (DuoVideo
H.239 or BFCP) including PC presentations using
VGA, SVGA and XGA resolutions
Simple to configure, Plug-and-Play technology
Supports network and video equipment from
multiple vendors
Outbound, Inbound, and Caller ID password
protection
Supports widescreen HD resolution (1280x720p)
Flexible design as MCU, Gateway or hybrid
Highest level of standards based embedded
encryption
Supports TANDBERG Expressway
TM
traversal, H.460.18 and H.460.19.
Quick
Using
Installation
Setup
the MPS
TF
,
firewall
System
System
Status
Configuration
1
Gateway
MCU
Technical
Configuration
Configuration
Descriptions
Appendices
MPS

Advertisement

Table of Contents
loading

Summary of Contents for TANDBERG Media Processing System MPS 200

  • Page 1 • Supports widescreen HD resolution (1280x720p) • Flexible design as MCU, Gateway or hybrid • Highest level of standards based embedded encryption • Supports TANDBERG Expressway firewall traversal, H.460.18 and H.460.19. Quick Using System Setup the MPS Status System...
  • Page 2 MPS 200 MPS 800 Finding the Information You Need Thank you for choosing TANDBERG! The TANDBERG MPS (Media Processing System) We recommend that you check the TANDBERG web site regularly for updated has been designed to provide you with many years of safe, reliable operation.
  • Page 3: Table Of Contents

    Environmental Issues ... 15 Environmental Issues - RoHS Table ... 16 Features Overview & MPS Capacity ... 17 TANDBERG MPS at a Glance ... 18 Precautions, Unpacking and Mounting ... 20 MPS 200 with 2 Media Processing Boards - Front Side ... 21 MPS 200 with ISDN and V.35 Network Cards - Rear Side ...
  • Page 4 Ports and Packet Sizes ... 162 Secure Conference (Encryption) ... 163 System Management Tools ... 164 System Management and Security ... 165 Appendices Technical Specifications ... 167 TANDBERG MPS 200 (1:2) ... 167 TANDBERG MPS 800 (1:2) ... 169 Quick Using System System...
  • Page 5: D 13373.08

    MPS 200 MPS 800 Introduction The TANDBERG MPS enables sites on IP (H.323 and SIP), We recommend that you check out the TANDBERG web site regularly for updated ISDN and High Speed Serial (V.35/RS449/RS530 w/RS366 versions of this manual: support) to participate in meetings with each other and http://www.tandberg.com/support/...
  • Page 6 • Dual Video Stream • Early media • Floor control • Feature parity to TANDBERG Video Systems with software version F5/F6 • Gateway Support for OD/HD • H.264 w288p, 400p, w448p, w576p, w720p • H.263 w288p, 400p, w488p, w576p Video •...
  • Page 7: Disclaimer, Patent Info, License Agreement Trademark & Copyright

    License Agreement All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be repro- duced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, or other- wise, without the prior written permission of TANDBERG.
  • Page 8 (c) UNIX System Laboratories, Inc. Amended / Expanded Copyright notices for third- All or some portions of this file are derived from ma- party software on the TANDBERG MPS systems are terial licensed to the University of California by Ameri- listed below: can Telephone and Telegraph Co.
  • Page 9 System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE GRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE STATED IN WRIT- ING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES PROVIDE THE PROGRAM “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR...
  • Page 10 Gert Doering Jakob Schlyter Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Jason Downs Juha Yrjölä Michael Stone Networks Associates Technology, Inc. Solar Designer Todd C. Miller Wayne Schroeder William Jones Redistribution and use in source and binary forms,...
  • Page 11 Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE thor’s web site: http://www.ijs.si/software/snprintf/ xSupplicant (wpa_supplicant) 802.1x Copyright (c) 2002-2005, Jouni Malinen jkmaline@ cc.hut.fi xSupplicant is distributed under the terms of xSupplicant license, which is a BSD style open source license.
  • Page 12 System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAM- AGES (INCLUDING, BUT NOT LIMITED TO, PROCURE- MENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;...
  • Page 13 System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Except as contained in this notice, the name of the X Consortium shall not be used in advertising or otherwise to promote the sale, use or other dealings in this Software without prior written authorization from the X Consortium.
  • Page 14: Safety Instructions

    Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE • If the apparatus has been exposed to rain or moisture • If the apparatus has been subjected to excessive shock by being dropped • If the cabinet has been damaged •...
  • Page 15: Environmental Issues

    CD version. Instead of a range of different user guides, there is now one CD – which can be used with all TANDBERG products – in a variety of languages. The environmental benefits of this are significant.
  • Page 16: Environmental Issues - Rohs Table

    Introduction Environmental Issues - RoHS Table Table of Introduction Main Installation Contents D 13373.08 NOVEMBER 2007 China RoHS Table Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 17: Features Overview & Mps Capacity

    Endpoints feature set. Therefore in this manual, we will not supporting these protocols will receive use the term TANDBERG MPS to refer to both main stream. models, unless a specific situation requires referring to each model with its own name.
  • Page 18: Tandberg Mps At A Glance

    4 Light Emitting Diodes (LEDs) for board status. With the TANDBERG MPS 800, there is sup- port for up to 8 Media Processing Boards. With the TANDBERG MPS 200, there is support for up to 2 Media Processing Boards. See the Technical Descrip- System Control- tion section for further details on the Board.
  • Page 19: D 13373.08

    Installation This section describes the first time installation of the MPS We recommend that you check the TANDBERG web site regularly for updated - Media Processing System. The section covers unpacking, versions of this manual: what’s in the box, mounting the MPS, cable connections, http://www.tandberg.com/support/...
  • Page 20: Precautions, Unpacking And Mounting

    Use a grounded AC power outlet for the TANDBERG MPS. Mounting the MPS on a Rack The TANDBERG MPS comes with 4 screws and 4 nuts for mounting in standard 19” racks. The chassis is equipped with brackets. Before starting the rack mounting, please make sure the TAND- BERG MPS is placed securely on a hard, flat surface.
  • Page 21: Mps 200 With 2 Media Processing Boards - Front Side

    USB 1 LEDs for the media board Quick Using System Setup the MPS Status LEDs for CPU and FAILURE RESET button System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Media Processing Boards System Controller Board (in slot 1) Appendices...
  • Page 22: Mps 200 With Isdn And V.35 Network Cards - Rear Side

    Using System Setup the MPS Status Bracket for Rack Mounting (in front) Voltage / Frequency Information Power Switch On/Off AC Power Inlet PRI E1/ T1 ISDN Network Interface Card System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 23: Mps 800 With 8 Media Processing Cards - Front Side

    LEDs for Enter/OK key power status 8 Media Processing Boards Quick Using System Setup the MPS Status Screw holes for Rack Mounting LEDs for the media board Ethernet Connectors System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 24: Mps 800 With Isdn And V.35 Network Cards - Rear Side

    D 13373.08 NOVEMBER 2007 Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE 2 V.35 Serial Interface Cards 2 PRI E1/T1 ISDN Net- work Interface Cards System Controller Board (slot 1) Bracket for Rack Mounting (in front)
  • Page 25: Connecting Cables

    Connect to Two Separate IP Networks If you want to connect the TANDBERG MPS to two separate IP networks you must use the second ‘Enet2’ interface on the back of the System Controller Board, in addition to the ‘Enet1’...
  • Page 26: D 13373.08 November

    Installation Starting the System Starting the System Preparations Before starting the TANDBERG MPS make sure the following has been done: System Controller Board must be installed in the first slot in the chassis. Make sure the Media Processing Board(s) Network Interface Card(s) and the interted correctly into the chassis.
  • Page 27: Lcd Menu Structure

    Restart To activate changes to the Parameter Config the MPS requires a restart. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 28: System Controller Board - Parameter Configuration

    Initial Configuration System Controller Board - Parameter Configuration Initial Configuration  Before using the TANDBERG MPS it requires • Press any key to open the main menu. some basic configuration. This is done through the Liquid Crystal Display (LCD) on •...
  • Page 29: Media Processing Board - Parameter Configuration

    Initial Configuration Media Processing Board - Parameter Configuration Initial Configuration  Before using the TANDBERG MPS it requires • Press any key to open the main menu. some basic configuration. This is done through the Liquid Crystal Display (LCD) on •...
  • Page 30 Quick Setup of the MPS The Quick Setup section will help you get your MPS online and We recommend that you check the TANDBERG web site regularly for updated operational quickly. It provides a step-by-step guide to the basic versions of this manual: H.323 services setup via the MPS web interface.
  • Page 31 SSH or Telnet by using a comprehensive The Overview page set of API commands. This enables the lets you see informa- TANDBERG MPS to be controlled by a different tion about all confer- user interface, such as an AMX or Crestron ences currently active control systems.
  • Page 32: Simple Ip Configuration

    IP Address Interface 2 If applicable, set the As a minimum you must configure Interface 1. If your TANDBERG MPS is connected to two different IP networks, you must configure both Interface 1 and Interface 2. Please refer to section System Configuration >...
  • Page 33: Simple H.323 Configuration

    Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Simple H.323 Configuration  Save - Press the Save button to save changes. Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 34: Simple Pri Configuration

    Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Simple PRI Configuration  Save - Press the Save button to save changes. Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 35: Simple Dial In Configuration

    MPS to know which confer- ence number to dial into. • ISDN Number. The ISDN number must be a valid PRI number of the TANDBERG MPS at hand. • E.164 Alias. The H.323 E.164 numeric alias for each conference.
  • Page 36 The Using the MPS section will help you understand how to use the We recommend that you check the TANDBERG web site regularly for updated MCU, Gateway and Phone Book. It provides a step-by-step guide to versions of this manual: the basics as well as a description of each setting available from the http://www.tandberg.com/support/...
  • Page 37 0 telephone calls are connected to the MCU. The indicate that 0 video calls are connected to the TANDBERG MPS. The indicate that 0 ISDN channels are used on the TANDBERG MPS. indicate that 0 kbps bandwidth is used on the TANDBERG...
  • Page 38 Indicates that DES (56 bit) encryption is used. Indicates that AES (128 Participants can dial in bit) encryption is used. Incoming calls are not Indicates that the confer- ence is not encrypted. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 39 System the MPS Setup Status Configuration ADMINISTRATOR GUIDE Create New Conference Create Conference 1 Create Confer- All settings on the ence # view will be explained in detail on the following pages. System Gateway Technical Configuration Configuration Descriptions TANDBERG Appendices...
  • Page 40: Conference Configuration (1:2)

    [Inactive]. Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Use Template to add participants or to Predefined conference configurations can be used by selecting one of the 10 predefined Conference templates Create Conference in the pane.
  • Page 41 When defining a conference, a specific billing code can be assigned to the conference. All calls in this conference will be associated with this billing code. This will allow man- agement tools, such as the TANDBERG Management Suite, to use the code for billing purposes.
  • Page 42: Video Settings (1:5)

    4 + 1 Split Wide 6 Split Wide Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE 4 Split 4 + 3 Split 5 + 1 Split 8 + 2 Split 8 + 2 Split 8 + 2 Split Bottom-Top Bottom...
  • Page 43 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel to add partici- Select Cancel to discard all changes Conference Over- and return to the view page.
  • Page 44 Status Add Participants Cancel Select Add Participants to add participants Select Cancel or to manually dial a participant. return to the System Gateway Configuration Configuration Configuration TANDBERG ADMINISTRATOR GUIDE to discard all changes and Conference Overview page. Technical Appendices Descriptions...
  • Page 45 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel to add participants Select Cancel to discard all changes and Conference Overview return to the Gateway Technical...
  • Page 46 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel Add Participants to add Select Cancel to discard all Con- changes and return to the ference Overview page.
  • Page 47: Audio Settings

    Set to Normal to remove weak echo. High: Set to High to remove strong echo. Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel Select Cancel to discard all changes Conference Over- and return to the view page. Gateway...
  • Page 48: Security Settings (1:2)

    Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel to add participants Select Cancel to discard all changes and Conference Overview return to the Gateway Technical...
  • Page 49 Security Settings (2:2) Encryption When set to On all participants in the conference must support DES or AES encryption (available on all TANDBERG endpoints using software version B4.0 or later). Participants not supporting encryption will be shown the ‘Encryption Required’ screen for 60 seconds before they are disconnected from the conference.
  • Page 50: Participants Settings

    Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel to add participants Select Cancel to discard all changes and Conference Overview return to the Gateway Technical...
  • Page 51: Network Settings

    Add Participants Cancel Add Participants Cancel Select to add partici- Select to discard all changes pants or to manually dial a participant. and return to the view page. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Conference Over- Appendices...
  • Page 52: Mcu Overview > Manage An Active Conference

    Push the Refresh button to manually refresh the page. Select: Select a conference from the list and press the the view to show the selected confer- ence. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE button to change Appendices...
  • Page 53: Conference Status (1:2)

    Create Conference and in the Conference Template Configuration. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Cre- Using Quick System the MPS Setup Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 54 System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Dual Video Stream Snapshot Snapshot Shows a snapshot of the Dual Video Stream transmitted from the MCU to the participants. Click on the picture to enlarge it in a separate window.
  • Page 55: Add Participants (1:3)

    The Manual Dialling is explained on the next page. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 56 2x64 kbps and 2x56 kbps calls. Leave blank (default) if the endpoint only has one number. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 57 (optional). • Specify which V.35 port to use (mandatory). Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 58: Add Participants - Examples

    Example 6: V.35 RS366 Example 7: SIP Example with SIP: The SIP Alias must be registered to a SIP Server. 6700#4#6#0 SIP:j.doe@sip.tandberg.net Number: 384 kbps (the # of channels x 64 Call Type: N/A Restrict (56 kbps): N/A Second Number: N/A...
  • Page 59: Edit Conference Settings

    To see a full description of each setting go to the MCU Overview > Create Conference section. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 60: Dial In Direct (Did)

    Protected Numbers configured in this dialog will be allowed to join this conference. Using Quick System the MPS Setup Status The Protect setting is set to Off (default) and the Protected Number field is not shown. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 61: The Basic View (1:3)

    SIP calls): The participant is transmitting audio. The participant has muted the microphone. The participant is connected as a telephone. The conference administrator has manually muted the participant. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 62 The participant has requested the floor or has been assigned the floor by the conference administrator and is transmitting video to all the other participants. Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 63 This button is only shown if the video has been muted by the confer- button. This button ence administrator. To add a participant to the TANDBERG MPS Phone Book press the Phone Book Audio Input Level button. This but- Shows the measured input level from each of the confer- ence participants.
  • Page 64: The Advanced View

    Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Click on a participant name to show the Call Info page. Need a snapshot Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 65: The Terminal List View

    By simply dialling from one TANDBERG MPS to other TANDBERG MPSs one will achieve a distributed setup. Master/Slave The TANDBERG MPS dialling out will be defined as the Master MCU. All other MCUs will be defined as Slave MCUs. For details about cascaded MCUs see Distributed MCUs Technical Descriptions section.
  • Page 66: The Change View

    Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE FUR Block The conference administrator can block FUR (Fast Update Request) for a participant. This will prevent Fast Update Requests for the participant. • Block Press the button in the FUR Block column to block fast update request for the selected participant.
  • Page 67: Gateway Features And Capacity

    1792 kbps remaining for lower rate calls 1536 kbps Max 2 calls This would be 6144 kbps total which leaves 1536 kbps remaining for lower rate calls 1920 kbps Max 2 calls System Gateway Configuration Configuration Configuration TANDBERG ADMINISTRATOR GUIDE Technical Appendices Descriptions...
  • Page 68: Gateway Usage Information

    Gatekeeper. The Gatekeeper will then try to route calls through other Gateways. This is done to maintain availability for incoming ISDN calls when using multiple Gateways. NOTE! This setting is not present if the MPS is a combo MCU/Gateway. System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 69: Gateway Calls Overview

    Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Actions When a call is active, the Administrator or Operator can disconnect the call, or transfer the call from one IP endpoint to another. Disconnect Gateway Call Will disconnect the selected gateway call.
  • Page 70: Gw Overview > Manage A Gateway Call

    Disconnect Call Press the ton to disconnect the selected Gateway call. A confirmation window will be shown: • Press to Disconnect the call • Press Cancel to discard the action System Gateway Technical Configuration Configuration Descriptions TANDBERG actions but- Appendices...
  • Page 71: Transfer A Call

    Transfer Call Press button to initiate the transfer • Press the Cancel button to discard the transfer. If the transfer fails the call will be discon- nected. System Gateway Technical Configuration Configuration Descriptions TANDBERG Gate- actions button. alias into the Appendices...
  • Page 72: Using The Phone Book

    Edit Entry dialog box. Delete: Select an entry from the list and press the Delete button to delete an entry. A confirmation dialog will show to let you confirm the action. System Gateway Technical Configuration Configuration Descriptions TANDBERG Appendices...
  • Page 73: Add New Entry

    • Mandatory for V.35 calls and G.703 Leased Line calls. Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Create New Select Create New save the new Phone Book Entry. are valid values (optional). Cancel Cancel Select...
  • Page 74: Edit Entry

    • Mandatory for V.35 calls and G.703 Leased Line calls. Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Save Select Save to save the changes to this Phone Book Entry. are valid values (optional). Cancel Cancel...
  • Page 75: Add New Group Entry

    Create New Create New Select Phone Book Group Entry. Using Quick System System the MPS Setup Status Configuration TANDBERG ADMINISTRATOR GUIDE Cancel Cancel to save the new Select to discard all changes and return to the Phone Book Gateway Technical Configuration...
  • Page 76: System Status

    System Status The System Status gives an overview of the status for the We recommend that you check the TANDBERG web site regularly for updated boards and cards installed on the MPS. The information will versions of this manual: reflect a fully equipped MPS and may differ from the MPS http://www.tandberg.com/support/...
  • Page 77: Isdn Pri Board Status

    102 Recovery On Timer Expiry 127 Interworking, Unspecified Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 ISDN PRI Board Status System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 78: G.703 Board Status

    Sync alert may indicate that the MPS or your G.703 network is not correctly configured. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 G.703 Board Status System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 79: Serial V.35 Board Status

    “On”. When a port is in the idle state this will show “Off”. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Serial V.35 Board Status System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 80: Media Board Ip Status

    Shows the temperature of the Media Processing Board in Fahrenheit. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Media Board IP Status System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 81: H.323 Status

    System Status H.323 Status IP Address Shows the IP address of the TANDBERG MPS con- figured for Network #1. H.323 Gatekeeper Status Shows status and IP address of the Gatekeeper for Network#1, which the TANDBERG MPS is registered to. •...
  • Page 82: Sip Status

    FAILED - The SIP server failed to register the URI Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 SIP Status System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 83: System Information (1:3)

    System Status System Information (1:3) System Unit • Product Type - Shows the TANDBERG product type • Product ID - Shows the TANDBERG product id • Up Time in Seconds - Shows the uptime since last boot in seconds •...
  • Page 84 Boot Software - Shows the boot software id for the MPS Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 MCU, Gateway, Hardware System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 85 MAC Address - Shows the Ethernet MacAddress(es) • Ethernet Speed - Shows the Ethernet speed(s) Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Used Resources System Quick Using System Status Setup the MPS Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 86: System Configuration

    MPS 200 MPS 800 System Configuration The System Configuration section contains information about We recommend that you check the TANDBERG web site regularly for updated how to configure and maintain the MPS. versions of this manual: http://www.tandberg.com/support/ documentation.php Table of...
  • Page 87: H.320 Board

    Enter a compulsory textual description to easier identify each card. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration Save Press the button to save changes Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 88: Pri Board

    The TANDBERG MPS will not send <Sending Com- plete> (Default: Off). Send Number The TANDBERG MPS will send its own number to the far end. This is only useful when each conference have specified a Dial In number (Default: On).
  • Page 89 Technical Descriptions. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration Save - Press the Save button to save changes. Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 90 (Default: Off). Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration Save - Press the Save button to save changes. Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 91: Pri Interfaces (1:3)

    If set to on, the PRI interface (IF #) is enabled (Default: On). Max Channels Indicates the maximum number of B-channels the TANDBERG MPS is allowed to use for each of the PRI-interfaces. • For E1 (ETSI/Euro ISDN), the maximum number of chan- nels is 30.
  • Page 92 Specifies where the TANDBERG MPS will start searching for available B-channels for each PRI-line for an outgoing call. High: If set to High, the TANDBERG MPS will start to search for available B-channels at the highest numbered B-channel (Default: High)
  • Page 93 Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration - continued: PRI Board Configuration Save - Press the Save button to save changes. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 94: E1/T1 Interfaces

    If set to Off, the E1 CRC4 is disabled. If your network equipment does not support this feature, turn it Off. T1 Cable Length Specifies the cable length between the TANDBERG MPS and the CSU for each of the PRI lines (only valid for T1 networks). Possible values are: •...
  • Page 95: G.703 Board

    If set to Off, the port is disabled for G.703 use. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration Save - Press the Save button to save changes. Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 96 4 (256 k) Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration Save - Press the Save button to save changes. Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 97: Ip Board

    The MCU will connect to the LAN using 100 Mbps/ Half Duplex. 100Full: The MCU will connect to the LAN using 100 Mbps/ Full Duplex. If forcing the TANDBERG MPS to anything other than Auto then the Ethernet switch must also be forced to match. Table of Main...
  • Page 98: Dns Interfaces, Ip Services

    - Press the Save button to save changes. Restart - For the settings to take effect the unit must be restarted after pressing the Save button. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 99: Media Board Ip Configuration

    Half Duplex. 100Full: The MCU will connect to the LAN using 100 Mbps/ Full Duplex. If forcing the TANDBERG MPS to anything other than Auto then the Ethernet switch must also be forced to match. Address The IP Address defines the network address of the Media Board.
  • Page 100: Serial V.35 Board Interfaces

    Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Restrict, port 1-32 When set to On, call rates are increment- ed in steps of 56 kbps. Off: When set to Off, call rates are increment- ed in steps of 64 kbps. (Default: Off)
  • Page 101: H.323 Configuration

    Net 2 When dialling directly in to a conference from H.323, this requires the use of H.323 numbers. To achieve this the TANDBERG MPS must be registered to a Gatekeeper. Gatekeeper: Set Gatekeeper to Gatekeeper to enable the MPS to register to a Gatekeeper.
  • Page 102: Snmp Configuration

    The SNMP Community name is case sensitive. System Contact Used to identify the system contact via SNMP tools such as TANDBERG Management Suite or HPOpenView. System Location Used to identify the system location via SNMP tools such as TANDBERG Management Suite or HPOpenView.
  • Page 103: Sip Configuration

    - Press the Save button to save changes. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Current RFC’s and Drafts Supported Read about the Current RFC’s and Drafts Supported for SIP in the Ap- pendices section. Gateway...
  • Page 104: Qos Configuration

    Quality of Service not active. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Network Configuration Save - Press the Save button to save changes. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 105: Miscellaneous Configuration

    Miscellaneous Configuration Miscellaneous Configuration Configuration - System name To change the System Name of the TANDBERG MPS, enter the new system name in the <System Name> field. Services The IP services can be independently disabled to prevent ac- cess to the TANDBERG MPS.
  • Page 106: Software Upgrade

    Upgrade Software Upgrade Software Upgrade New software to the TANDBERG MPS can be installed via the Software Upgrade web page. The Software Upgrade page shows the current software ver- sion, the hardware serial number and the installed options and the option keys.
  • Page 107: Language

    Delete button is replaced with the text “Predefined file“. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Browse Press the Browse button to find a file. Upload Press the Upload button to upload the file. Gateway Technical...
  • Page 108: Dialog Pictures

    Delete button is replaced with the text “Predefined file“. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Browse Press the Browse button to find a file. Upload Press the Upload button to upload the file. Gateway Technical...
  • Page 109: Dialog Sounds, Symbols

    Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE The logo will not be present in conferences which have enabled and are using optimal Voice Switch, oVS. Browse To add a new file, press to find the file, and then press Upload .
  • Page 110: Xml Document

    Example: Text is copied from the command.xml file and pasted into the XML Document editor field. Save - Press the Save button to save changes. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 111: Certificate Management

    - Press the Upload button to upload the HTTPS certificate, Private key and Passphrase (if used). NOTE - The MPS must be restarted for the new certificate to take affect. System Quick Using System Configuration Setup the MPS Status TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 112 The Gateway Configuration section contains information about how to We recommend that you check the TANDBERG web site regularly for updated configure and use the Gateway on the TANDBERG MPS. Reading this versions of this manual: section makes you familiarize yourself with the configuration menu http://www.tandberg.com/support/...
  • Page 113: Gateway Functionality And Dialling Rules

    System Configuration > Upgrade section. About the Option Key An option key for the Gateway can be obtained through the regular TANDBERG channels. The op- tion key states how many Gateway sessions the MPS is able to run in parallell. Gateway Sessions...
  • Page 114: Dialling Rules

    However, bear in mind that the total number of registrations on the Gatekeeper can be limited. For further information about how the video system endpoint supports TCS-4 please see the MXP Administrator’s Guide on http:// www.tandberg.com. Table of Main Introduction Installation Contents D 13373.08...
  • Page 115: Examples With Isdn Gateway

    It is also possible to configure an H.323 to • To Prefix instead ISDN Gateway. For further information about how the video system endpoint supports TCS-4 please see the MXP Administrator’s Guide on http://www.tandberg.com. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007...
  • Page 116: Examples With V.35 Gateway

    Slot 12 & Port 30: 0630 Slot 12 & Port 31: 0631 Slot 12 & Port 32: 0632 For further information about how the video system endpoint supports TCS-4 please see the MXP Administrator’s Guide on http://www.tandberg.com. Table of Main Introduction Installation Contents D 13373.08...
  • Page 117: Examples With G.703 Gateway

    Slot 6 Port 8 Call 3: 06083 Slot 6 Port 8 Call 4: 06084 Slot 6 Port 8 Call 5: 06085 For further information about how the video system endpoint supports TCS-4 please see the MXP Administrator’s Guide on http://www.tandberg.com. Table of Main Introduction Installation Contents D 13373.08...
  • Page 118: Gateway Configuration (1:3)

    - Press the Save button to save changes. Restart - For the settings to take effect the unit must be restarted after pressing the Save button. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 119 - Press the Save button to save changes. Restart - For the settings to take effect the unit must be restarted after pressing the Save button. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 120 - Press the Save button to save changes. Restart - For the settings to take effect the unit must be restarted after pressing the Save button. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 121: File Management

    Delete button is replaced with the text “Predefined file“. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Browse Press the Browse button to find a file. Upload Press the Upload button to upload the file. Gateway Technical...
  • Page 122 The MCU Configuration section contains information about how to configure We recommend that you check the TANDBERG web site regularly for updated and use the MCU on the TANDBERG MPS. Reading this section makes you versions of this manual: familiarize yourself with the configuration menu and functions important http://www.tandberg.com/support/...
  • Page 123: About The Dial In Numbers Menu

    The TANDBERG MPS 800 (200) supports up to 40 (10) simultaneous conferences. Single Dial In Number The Single Dial In Number enables users to set up multiple conferences in an Ad Hoc manner using one single number to the MPS.
  • Page 124: Single Dial In Number Menu

    ISDN: The ISDN Single Dial In Number must be a valid PRI number of the TANDBERG MPS at hand. The IP address for Single Dial In Number must be a valid IP address on the TANDBERG MPS System Controller Card.
  • Page 125: Ad Hoc Conferences Menu

    System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Template Up to 20 conferences may be defined in the conference list, one with Access Password and one without Access Password, for each of the 10 templates. You can also select the same template severeal times.
  • Page 126: Static Conferences Menu

    NOVEMBER 2007 Static Conferences E.164 Aliases The H.323 E.164 numeric alias for each conference. The TANDBERG MPS must be registered to a Gatekeeper. ISDN The ISDN number must be a valid PRI num- ber of the TANDBERG MPS at hand.
  • Page 127: Personal Conferences Menu

    System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE SIP URI In this field, a unique SIP URI for the conference could be entered. You must be able to configure the SIP proxy to forward certain SIP URI to the MPS. Note that the full SIP URI should be entered and that functional- ity may be limited depending on the SIP server.
  • Page 128: Personal Conferences Menu

    Personal Conference. Edit Participants Edit Participans Press the the ton to open the Add Participants dialog to add or remove participants. Save Press the Save button to save changes to your configuration. System Gateway Technical Configuration Configuration Descriptions TANDBERG but- Appendices...
  • Page 129: Direct Ad Hoc Conferences Menu

    To attend the meeting the other group members dials the same number. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Add New Press the Add New button to add a Prefix and Conference Template for Prefix a new group of conferences to the configuration list.
  • Page 130: Network Profiles

    Network Profiles Network Profiles Network Profiles Network Profiles enables the user to specify a protocol and a service prefix for TANDBERG MPS dialling. Name Enter the name of the new Network Profile in the Name field. Call Prefix Enter the Call Prefix of the new Network Profile.
  • Page 131: Conference Template

    The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 132 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 133 4 + 1 Split Wide 6 Split Wide Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE 4 Split 4 + 3 Split 5 + 1 Split 8 + 2 Split 8 + 2 Split 8 + 2 Split Bottom-Top Bottom...
  • Page 134 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 135 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 136 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 137 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 138 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 139 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 140 Overview section. Encryption When set to On all participants in the conference must support DES or AES encryption (available on all TANDBERG endpoints using software version B4.0 or later). Participants not supporting encryption will be shown the ‘Encryption Required’...
  • Page 141 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 142 The Conference Templates are found in the MCU Configuration tab. The predefined settings will be used as default settings when creating new conferences based on this specific template. TANDBERG MPS enables the setup of 10 different conference templates. The conference template contains the same settings as de-...
  • Page 143 Delete button is replaced with the text “Predefined file“. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Browse Press the Browse button to find a file. Upload Press the Upload button to upload the file. Gateway Technical...
  • Page 144 Voice Switch, oVS. Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Legal File Formats At the bottom of the page, custom file requirements are listed for each of the file-types. Gateway Technical Appendices Configuration...
  • Page 145 Technical Descriptions This section gives you a detailed technical description of the We recommend that you check the TANDBERG web site regularly for updated System Controller Board, Media Boards and the different types versions of this manual: of Network Interface Boards. You will also find more information http://www.tandberg.com/support/...
  • Page 146: Network Interfaces

    Media Processing Boards and 2 Network must be connected to each network. Interface Cards. The 2 x LAN interfaces will also give the TANDBERG MPS support for two Gatekeepers, one on each network. Front Chassis The TANDBERG MPS chassis is 19” rack- mountable.
  • Page 147: Media Processing Board Interface

    You will also find 4 Light Emitting Diodes (LEDs) for power status. The backplane TANDBERG MPS 800 has support for up to 8 Media Processing Boards. of the chassis is provided with advanced TANDBERG MPS 200 has support for up to 2 Media Processing Boards.
  • Page 148: E1/T1 Network Interface Card (Iic-8) (1:3)

    Media Pro- by connecting to its J5-connector from the back of the is auto, meaning the first port with a clock. tells the TANDBERG MPS to take the clock from that Quick Using System...
  • Page 149 Service Unit) depending on the network layout. The Cable Length in the PRI configuration menu specifies the distance from the MCU to the CSU or last repeater. PRI Protocols The TANDBERG MPS supports the PRI protocols • AT&T Custom • National ISDN •...
  • Page 150 This will ensure that the MCU always have available channels on the first PRI number (which normally should be the MCUs main number). • The TANDBERG MPS supports simultaneous dial in to the same confer- ence on ISDN. Table of...
  • Page 151: V.35 Serial Interface Card (Sic-32)

    Media Processing Boards and 2 Network A Media Processing Board must be in front of each V.35 Serial Interface Cards. Interface Card. See the TANDBERG MPS 800 V.35 interface cards on how the V.35 Interface Cards are installed in the rear Front Chassis of the chassis.
  • Page 152: V.35 Serial Interface Card - Cable Description

    POS 18 Frontview Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE V.35 Pinout Table Plug B Signal Name Pair no Plug C Plug B Signal Name LOST SIG LOST SIG CLK TX + CLK TX +...
  • Page 153: Power Supplies

    They are installed at the back of the chassis. up to 8 Media Processing Boards and 4 If the MPS has more than 3 Media Processing Boards the TANDBERG Network Interface Cards. MPS is shipped with 3 hot-swappable power units.
  • Page 154: Mps 800 - Inserting Network Interface Cards

    ISDN/V.35 Interface Card. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Inserting Additional Network Interface Cards with TANDBERG MPS 800 Quick Using System Setup the MPS Status PRI E1/T1 ISDN Interface Card 4 x PRI E1/T1 ISDN Network Interface Cards on rear side 4 x Media Processing Cards in front V.35 Serial Interface Card...
  • Page 155: Mps 200 - Inserting Network Interface Cards

    Introduction Installation Contents D 13373.08 NOVEMBER 2007 Inserting Additional Network Interface Cards with TANDBERG MPS 200 PRI E1/T1 ISDN Interface Card 2 x PRI E1/T1 ISDN Network Interface Cards on rear side 2 x Media Processing Cards in front V.35 Serial Interface Card 2 x V.35 Serial Interface Cards on rear...
  • Page 156: Features

    Type of Service enables the user to define what type of connection that should be chosen for the Differential services is another method of QoS offered by TANDBERG IP traffic. Helps a router select a routing path that utilizes 6 bits of the Type of Services Byte. Differential services is when multiple paths are available.
  • Page 157: Tandberg Best Impression Tf

    /H.239/BFCP /H.239/BFCP may be sent in both Continous Precence and Voice Switched The TANDBERG MPS will transmit the same format as the one received if all the sites are capable of receiving it. The Video Format will fallback is as described for Voice Switched mode.
  • Page 158: Duovideo Tf , H.239, Bfcp

    Dual Video Stream is NTSC image over traditional CIF based disconnected. MCU. In the TANDBERG MPS there is support for mix H.263+ Widescreen formats of DuoVideo TANDBERG MPS support encoding of true conference. Other manufacturer’s systems sup-...
  • Page 159: Ip Adaptive Bandwidth Management

    TANDBERG MPS without having to The MCU regulates outgoing and incoming me- settle on the best common protocols.
  • Page 160: Intelligent Packet Loss Recovery

    Inband Changing of Video and Audio Algorithms Inband Changing of Video and Audio Algorithms TANDBERG MPS is able to change its video and audio algo- rithms ‘on the fly’ during a conference. This is valuable when switching between the live user image (CIF) and the live PC (XGA, SVGA, VGA).
  • Page 161: Distributed Mcus

    By simply dialling from one TANDBERG MPS to other TANDBERG MPSs one will achieve a distributed setup. In this case the TANDBERG MPS dialling out will be defined as the master MCU and all other MCUs as slaves. The connection between the MCUs (or the Endpoints) can be IP, ISDN or V.35.
  • Page 162: Miscellaneous

    HTTP traps to TMS Check system status SNMP Commands IP Packet Sizes Packet loss is displayed in the conference overview of the TANDBERG MPS, see Overview. The number shown is the average of audio- and video- packets that are lost System Gateway...
  • Page 163: Secure Conference (Encryption)

    MCU Overview > Encryption Mode • If Encryption Mode is set to Auto, the TANDBERG MPS accepts both AES and DES encryption. • If Encryption Mode is set to AES, all participants must have AES in order to join the conference.
  • Page 164: System Management Tools

    TANDBERG MPS giving access to all managing features of the MCU. Using a standard Web-browser (Mozilla The TANDBERG MPS can be managed in many Firefox, MS Internet Explorer 5.0 or later), the ways: user may perform all forms of meeting set-up •...
  • Page 165: System Management And Security

    System Management and Security HTTPS HTTPS Disable Services The TANDBERG MPS supports HTTPS in order For security reasons you may want to disable to ensure secure transmission of the informa- some of the services provided by the TAND- tion displayed on the administrator’s PC.
  • Page 166 Appendices The Appendices contain detailed technical specification on the MPS We recommend that you check the TANDBERG web site regularly for updated 800 and MPS 200 along with other information you may need to better versions of this manual: understand the TANDBERG MPS.
  • Page 167: Technical Specifications

    CP32) MCU CONFERENCE SCHEDULING Voice Switched Advanced scheduling (Multiple MCUs) with TMS Self-view optional Scheduling using the TANDBERG Scheduler, Microsoft Lecture mode Outlook® or IBM Lotus Notes® Embedded site naming with Unicode support On-demand conferencing (true Ad Hoc)
  • Page 168 H.221, H.231, H.241, H.242, H.243, H.245, H.320, TANDBERG and Expressway are registered trademarks H.239, H.323, BONDING (ISO 13871), Q.931, SIP, or trademarks of TANDBERG in the U.S. and other H261, H263+, H264, G711, G.722, G.722.1, G728, countries. MPEG4 AAC-LD All other trademarks are property of their respective owners.
  • Page 169: Tandberg Mps 800 (1:2)

    CP32) MCU CONFERENCE SCHEDULING Voice Switched Advanced scheduling (Multiple MCUs) with TMS Self-view optional Scheduling using the TANDBERG Scheduler, Microsoft Lecture mode Outlook® or IBM Lotus Notes® Embedded site naming with Unicode support On-demand conferencing (true Ad Hoc)
  • Page 170 H.221, H.231, H.241, H.242, H.243, H.245, H.320, TANDBERG and Expressway are registered trademarks H.239, H.323, BONDING (ISO 13871), Q.931, SIP, or trademarks of TANDBERG in the U.S. and other H261, H263+, H264, G711, G.722, G.722.1, G728, countries. MPEG4 AAC-LD All other trademarks are property of their respective owners.
  • Page 171 TANDBERG’s equipment. The test reports and certificates issued by the approval agen- cies show that the TANDBERG MPS complies with the following standards. EMC Emission - Radiated Electromagnetic Interference •...
  • Page 172 RFC 4629 RTP Payload Format for ITU-T Rec. H.263 Video • RFC 4796 The Session Description Protocol (SDP) Content At- tribute • draft-ietf-xcon-bfcp-connection-04.txt • draft-levin-mmusic-xml-media-control-08.txt • draft-ietf-sipping-cc-transfer-07.txt • draft-kristensen-avt-rtp-h264-extension-00.txt Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 173 Server (LCS) to work properly with the MPS. SIP (Session Initiated Protocol) Software version J3 and above for the TANDBERG MPS has support for the Session Initiated Protocol (SIP). The first version of support will be compatible with the Microsoft Live Communications Server (LCS) 2005, SP1.
  • Page 174 Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Configuring Microsoft Office Live Communications Server (LCS) 2005, SP1 Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 175 Quick Using System Setup the MPS Status User field. Transport is set to to save the route, and press again to close the Properties System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Port Appendices...
  • Page 176 Please refer to section System Configuration > IP Configuration more details. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 MPS DNS Configuration Quick Using System System Setup the MPS Status Configuration TANDBERG ADMINISTRATOR GUIDE Gateway Technical Appendices Configuration Configuration Descriptions...
  • Page 177 System Configuration > SIP Configuration for more details. Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 MPS SIP Configuration DNS Name Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 178 Table of Main Introduction Installation Contents D 13373.08 NOVEMBER 2007 Verification of SIP Server Active and Configuring of Dial In Numbers Routing Quick Using System Setup the MPS Status System Gateway Technical Configuration Configuration Configuration Descriptions TANDBERG ADMINISTRATOR GUIDE Appendices...
  • Page 179 Philip Pedersens vei 20, 1366 Lysaker, Norway Telephone: +47 67 125 125 Fax: +47 67 125 234 Video: +47 67 126 126 E-mail: tandberg@tandberg.com U.S. HEADQUARTERS 1212 Avenue of the Americas 24th Floor, New York, NY 10036 Telephone: +1 212 692 6500...

This manual is also suitable for:

Mps 200Mps 800Media processing system mps 800

Table of Contents