Trane BCHE Installation, Operation And Maintenance Manual page 98

Blower coil air handler
Table of Contents

Advertisement

ECM Overview and Setup
Table 33. Configuration settings of the motor control board (for reference only) (continued)
Description
User Interface
on Unit Label
Name
Mt1 Low PWM
M M 1 1 L L o o
Lt
Mt2 Hgh PWM
M M 2 2 h h i i
Lt
Mt2 Low PWM
M M 2 2 L L o o
Lt
Mt1 Ovspd RPM
r r p p m m 1 1
Mt2 Ovspd RPM
r r p p m m 2 2
Fan Proving Fct
F F P P r r v v
AI Boost Amp
A A i i S S c c
AI Floor
v v F F l l r r
PulsePerRev
F F d d b b k k
P Value Mtr 1
p p v v l l 1 1
I Value Mtr 1
I I v v l l 1 1
P Value Mtr 2
p p v v l l 2 2
I Value Mtr 2
I I v v l l 2 2
Ht Sens Mk Val
A A i i 2 2 m m
F
Ht Sens Bk Val
A A i i 2 2 b b
F
Ht Sens
A A i i P P u u
Resistor
Mt 1 Ramp
M M 1 1 r r p p
%/sec
Mt 2 Ramp
m m 2 2 r r p p
%/sec
98
Typical User Interface
Value
Sets the minimum maximum output
percentage that the controller will
1 1 4 4 .5 5
request from Motor 1.
Sets the maximum output percentage
9 9 0 0
that the controller will request from
Motor 2.
Sets the minimum maximum output
percentage that the controller will
1 1 4 4 .5 5
request from Motor 2.
Selects the rpm above which the
Motor 1 will be assumed to be in an
2 2 5 5 0 0 0 0
overspeed condition and will need to be
shut down.
Selects the rpm above which the
Motor 2 will be assumed to be in an
2 2 5 5 0 0 0 0
overspeed condition and will need to be
shut down.
Selects which mode should be assigned
to the Binary output circuit, depending
F F n n s s t t
on unit type.
Boosts or attenuates the analog input
1 1
signal to compensate for long wire runs.
Rejects noise on the analog input lines
and sets up the motor control board to
0 0 .5 5
turn on if the thermostat or controller is
commanding its analog outputs on.
Sets up the tachometer function to be
compatible with the on-board motor and
1 1 8 8
for correct speed calculation and
calibration.
Sets up the on board closed loop
control to control Motor 1 with proper
0 0 .0 0 3 3
stability.
Sets up the on board closed loop
control to control Motor 1 with proper
0 0 .0 0 3 3
stability.
Sets up the on board closed loop
control to control Motor 2 with proper
0 0 .0 0 3 3
stability.
Sets up the on board closed loop
control to control Motor 2 with proper
0 0 .0 0 3 3
stability.
Sets the make value for the motor
control board triac output based on the
8 8 5 5
thermistor input.
Sets the break value for the motor
control board triac output based on the
9 9 0 0
thermistor input.
Sets the input impedance of the
o o u u t t
thermistor input.
Sets the ramp rate for Motor 1, in % per
3 3
second.
Sets the ramp rate for Motor 2, in % per
3 3
second
Description
This envelope protection value should not be
altered.
This envelope protection value should not be
altered.
This envelope protection value should not be
altered.
This envelope protection value should not be
altered.
This envelope protection value should not be
altered.
This setting has to be correct for proper unit
operation of electric heat and changeover units.
A value of 1 1 should be used if no voltage level
compensation is needed (i.e., voltage peak is at
10 VDC).
Do not change this setting as this is critical to
proper unit operation.
Do not change this setting.
Do not change this setting.
Do not change this setting.
Do not change this setting.
Operation also depends on F F p p r r v v , A A i i 2 2 B B , and
A A i i p p u u settings.
Operation also depends on F F p p r r v v , A A i i 2 2 m m , and
A A i i p p u u settings.
Should be pre-set to "OUT" for Tracer
controllers.
®