Installing A 5-Conductor Pentarod Probe - Genesis ED1 Installation And Operating Manual

Table of Contents

Advertisement

Pentarod Probe
end view
8
• Process temperature, pressure, dielectric, and viscosity are
within the probe specifications for the installation. See
Specifications, Section 2.6.
• Ensure that the nozzle does not restrict performance by
ensuring the following:
Nozzle I.D. is > 71 mm (2.8") diameter.
1. Ensure that the process connection is the correct flanged or
threaded mounting.
2. Carefully place the probe into the vessel. Properly align the
gasket on flanged installations. Refer to drawing indicating
lifting points shown at left.
3. Align the probe process connection with the threaded or
flanged mounting on the vessel.
4. Tighten threads of flange bolts.
5. Proceed to Probe Electronics Wiring, Section 1.4.6.

1.4.5 Installing a 5-conductor Pentarod Probe

(Model PxF)
Before installing, ensure that the:
• The model and serial numbers shown on the nameplates of
the Genesis main electronics and probe are identical. For
optimal performance (and correlation to the Calibration
Certificate included with all units), devices and probes
should be installed as a matched set.
• Probe has adequate room for installation and has unob-
structed entry to the bottom of the vessel.
• Process temperature, pressure, dielectric, and viscosity are
within the probe specifications for the installation. See
Specifications, Section 2.6.
• Ensure that the nozzle does not restrict performance by
ensuring the following:
• Nozzle is > 75mm (3") diameter.
1. Ensure that the process connection is the correct flanged or
threaded mounting.
2. Carefully place the probe into the vessel. Align the gasket
on flanged installations. Refer to drawing indicating lifting
points shown at upper left.
3. Align the probe process connection with the flanged
mounting on the vessel.
4. Tighten flange bolts.
5. Proceed to Probe Electronics Wiring, Section 1.4.6.
63-601 Genesis Models ED1 & ED2 Multiphase Detector

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ed2

Table of Contents