2.6.1 Functional/Physical

Environment
Operating Temperature
Storage Temperature
Humidity
Electromagnetic Compatibility
Surge Protection
Shock/Vibration
Performance
Reference Conditions
Linearity
Accuracy
Response Time
Initialization Time
¿
Pentarod probes must be used in metallic vessel or stillwell to maintain CE noise immunity.
38
-40 to +70 °C (-40 to +160 °F); LCD viewable -20 to +70 °C (-5 to +160 °F )
-45 to +85 °C (-50 to +185 °F)
0 to 99%, non-condensing
Meets CE requirement (EN 61326) and NAMUR NE 21 ¿
Meets CE EN 61326 (1000V)
ANSI/ISA-S71.03 Class SA1 (Shock); ANSI/ISA-S71.03 Class VC2 (Vibration)
Reflection from liquid with a 3 meter (10 foot) probe at +20 °C (+70 °F)
Application dependent
Application dependent
Approximately 15 seconds
Less than 30 seconds