Probe Selection Guide; Probe Specifications - Genesis ED1 Installation And Operating Manual

Table of Contents

Advertisement

2.6.2 Probe Selection Guide

ENLARGED COAXIAL PROBE
Probe¿ Description
Application
Enlarged
PxC
Coaxial
PxF
5-Conductor
¿ 2
nd
digit E=English, M=Metric
¡ Genesis probes containing o-rings can be used for vacuum (negative pressure) service, but only
those probes with glass seals are hermetically sealed to <10

2.6.3 Probe Specifications

Model
Materials
Diameter
Process
Connection
Transition Zone
(Top and Bottom)
NOTA: Top Transition Zone: The detector may still operate but levels reading may become non-linear.
Bottom Transition Zone: Detector will not measure levels in this area.
Temperature/Pressure Charts
PxC and PxF
Temperature/Pressure Ratings
1200
1000
800
600
400
200
0
0
100
200
Temperature (°F)
63-601 Genesis Models ED1 & ED2 Multiphase Detector
Installation
Coaxial GWR Probes— Liquids
Interface
Tank
-8
cc/sec @ 1 atmosphere helium.
Enlarged Coaxial
(PxC)
316/316L SS (Hastelloy C)
1.75" (44 mm) diameter
3" ASME or EN flanges
300
400
500
PENTAROD PROBE
Dielectric
Temperature
Range
Range
-40 to +200 °C
ε
1.4 –100
r
(-40 to +400 °F)
5-Conductor
(PxF)
TFE spacers,
Viton
®
O-rings
3" NPT, 3" BSP
200 mm (8")
Temperature
°C (°F)
-40 (-40)
21 (+70)
38 (+100)
93 (+200)
149 (+300)
204 (+400)
Vacuum ¡
Max.
Viscosity
Pressure
cP (mPa.s)
1000 psi
Yes
(70 bar)
10000
Pressure (316 SS)
bar (psi)
52 (750)
70 (1000)
70 (1000)
45 (650)
28 (400)
19 (270)
2000
39