Configuration
7.1 Management Explorer
7.1.11.2

Firmware version

Note
The following functions will not be available on all SIMATIC IPC models.
Assigning and changing inventory numbers
You can assign inventory numbers to your devices or change assigned inventory numbers for
internal administrative purposes.
1. Start the Management Explorer.
2. In the menu bar, select "Tools > Local BIOS...".
3. Select the "Update" tab.
4. Click the "Change" button in the "Inventory number" field.
5. Assign a new inventory number or change an existing inventory number and confirm your
entry.
6. Restart the device.
Result
The inventory number is now permanently saved in the device SMBIOS.
The inventory number is located in SMBIOS under "System Enclosure" as entry
"Asset Tag Number".
CPU 1515SP PC / CPU 1515SP PC2
Requirement for a firmware update with CPU 1515SP PC / CPU 1515SP PC2:
• The S7-1500 software controller must be in STOP mode.
• The CPU must be booted in Windows mode.
Performing a firmware update
Note
Irreparable damage to the firmware
An incorrectly executed firmware update can irreparably damage the firmware. You may only
start a firmware update if it is absolutely necessary. The following applies:
• Never interrupt the power supply while an update is taking place.
• The update process must be complete before you shut down the device.
46
SIMATIC IPC DiagMonitor V5.1.6
Operating Manual, 05/2021, A5E50981422-AA