Connect Power to an AC-Powered Services Gateway

Copyright © 2011, Juniper Networks, Inc.
NOTE: The device is not shipped with AC power cords. Make sure that you
order or obtain AC power cords with plugs that are appropriate for your
geographical location.
Connect Power to an AC-Powered Services Gateway on page 17
Connect Power to a DC-Powered Services Gateway on page 18
WARNING: The device must be properly grounded before you connect the
AC power cords.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis. For more information about ESD,
see the SRX3600 Services Gateway Hardware Guide.
Locate the power cords you will use to connect the device to AC power. See the
2.
SRX3600 Services Gateway Hardware Guide for specifications.
For each power supply:
3.
Insert the appliance coupler end of the power cord into the appliance inlet on the
a.
power supply.
Insert the power cord plug into an external AC power source receptacle.
b.
NOTE: Each power supply must be connected to a dedicated AC power
feed and a dedicated external circuit breaker. We recommend that you
use a 15 A (250 VAC) minimum, or as permitted by local code.
Snap the wire bail over the power cord as shown in Figure 15 on page 18 to prevent
c.
the power cord from accidentally disengaging.
Dress the power cord appropriately. Verify that the power cord does not block the
d.
air exhaust and access to services gateway components or drape where people
could trip on it.
Connect Power to an AC-Powered Services Gateway
17