Meaning
The USB flash drive is not inserted, or is inserted
incompletely.
USB Memory Not
The USB flash drive was removed after you selected data
Ready!
that was on the USB flash drive.
The format of the USB flash drive is invalid.
Storage Full!
There is insufficient space in the writing-destination.
The format of the file being imported is invalid or
unsupported.
Incorrect File!
This file cannot be installed because it is an EXPANSION for a
different model.
The sound file that you are attempting to install is damaged.
Not Found! Empty
During AUTO IMPORT of samples, there were not enough
PAD was not
empty pads for the samples being imported.
found.
Sample Too Long!
The allowable sampling time has been exceeded.
Sample Length Too
The sample is too short, and cannot be edited correctly.
Short!
Since the USB flash drive's lock setting is on, writing or
Storage Protected!
deletion is not possible.
There is a problem with the storage that is the target of the
Storage Error!
operation.
When using File Utility, the Copy/Move destination path is
Incorrect Path!
invalid.
Invalid File/Folder
The file or folder name includes characters that cannot be
Name!
handled by the FANTOM.
Invalid Char!
Unusable characters are included.
You have exceeded the maximum measures that can be
Pattern End!
realtime-recorded.
Sequencer Error!
A sequencer-related error has occurred.
Since the maximum number of notes that can be stored in a
Data Full!
pattern has been exceeded, no further recording or editing
is possible.
When recording a layer consisting of multiple zones, the
Pattern status is
recording-destination includes multiple tracks of differing
different!
pattern status.
Since the FANTOM is recording, this operation cannot be
Now Recording!
executed.
Since the FANTOM is playing, this operation cannot be
Now Playing!
executed.
The FANTOM cannot start up.
Program Version
The program cannot be loaded correctly. Alternatively, the
Error!
system update program might be incorrect.
An unusually large amount of MIDI data was received, and
MIDI Buffer Full!
could not be processed.
MIDI Offline!
The MIDI IN connection was broken.
Action
Turn off the power, insert the USB flash drive correctly, and then
turn the power on again (p. 25).
Use the FANTOM to format the USB flash drive (p. 159).
Delete unneeded data.
Use a file format that the FANTOM supports.
Audio files (WAV/AIFF/MP3) are supported (p. 97).
Use the sample DELETE function (p. 101) to prepare a sufficient
number of empty pads, and then try the operation again.
If the sample is extremely short, editing may not produce the
desired result.
Turn off the power, disconnect the USB flash drive, and turn off its
lock setting.
If the target storage is in
¹ A USB flash drive: Use the FANTOM to format the USB flash
drive (p. 159).
¹ INTERNAL STORAGE: Execute the INTERNAL STORAGE
INITIALIZE operation (p. 158).
¹ Sample memory: Execute the sample DELETE ALL operation
(p. 101).
In other cases, execute a factory reset (p. 160).
If this does not solve the problem, contact your dealer or
customer support.
A subfolder that includes the Copy/Move source cannot be
specified as the Copy/Move destination.
The FANTOM cannot handle files or folders whose name includes
the following characters.
Nor can it handle special characters such as double-byte
characters.
Do not use these characters.
Characters that cannot be handled by the FANTOM are shown in
the error message.
Do not use these characters.
Turn the power off and then on again before you proceed
(p. 25).
Use the pattern utility modify commands Delete or Erase to delete
unneeded data from the pattern that you're recording or editing
(p. 123).
If you are layer-recording tracks, make sure that the loop settings
(loop length, playback position, LOOP SW setting) for the patterns
of those tracks are consistent with each other (p. 112).
Stop recording before you execute the operation.
Stop playback before you execute the operation.
Using the correct program, perform the update once again.
If this does not solve the problem, contact your dealer or
customer support.
Reduce the amount of MIDI messages that are being transmitted.
Check that there is no problem with the MIDI cable connected
to the FANTOM's MIDI IN, and that the MIDI cable was not
disconnected.