Table 10. Components on the system board
Processor power connector
1
Note: The 2x2 pins marked in grey are for 300W PSU.
Processor
2
Processor heat sink fan power connector
3
Memory module slot 1
4
Memory module slot 2
5
Memory module slot 3
6
Memory module slot 4
7
Power button with LED connector
8
Mono amplifier (speaker) connector
9
System power connector
10
SATA power 1 connector
11
SATA power 2 connector
12
Front fan connector
13

RAID adapters

Use this information to locate the connectors on the optional RAID adapters.
Figure 10. Connectors on SATA/SAS RAID adapter (8i)
Note: The RAID adapter should be installed in PCIe slot 1.

Internal cable routing

Some of the components in the server come with internal cables meant for specific connectors.
Cable routing guidelines
Before connecting the cables, read the following guidelines carefully:
• Turn off the server before you connect or disconnect any internal cables.
• Refer to the documentation that comes with any external devices for additional cabling instructions.
• Make use of the identifiers printed on the cables to locate the proper connectors.
• Ensure that the cable is not pinched and does not cover any connectors or obstruct any components on
the system board.
3V battery (CR2032)
14
SATA 3 connector (drive bay 3)
15
SATA 4 connector (ODD drive)
16
SATA 2 connector (drive bay 2)
17
SATA 1 connector (drive bay 1)
18
M.2 connector
19
Thermal sensor connector
20
PCIe slot 3 (PCI Express 3.0 x4 )
21
PCIe slot 2 (PCI Express 3.0 x1)
22
PCIe slot 1 (PCI Express 4.0 x16)
23
Rear fan connector
24
Intrusion switch connector
25