BACNET
OBJECT ID
BV:9
Alarm State
BV:10
Capacity Clamp Mode
BV:11
Fan request from IGC
BV:12
Comp A1 Locked Out ?
BV:13
Comp A2 Locked Out ?
BV:14
Comp B1 Locked Out ?
BV:15
Comp B2 Locked Out ?
BV:16
Compressor A1 Relay
BV:17
Compressor A2 Relay
BV:18
Compressor B1 Relay
BV:19
Compressor B2 Relay
BV:20
Cool Mode Not In Effect?
BV:21
Override Modes in Effect
BV:22
Supply Fan not on 30s ?
BV:25
DBC - OAT Lockout?
BV:26
DCV Resetting Min Pos
BV:27
DDBC- OAT > RAT Lockout?
BV:28
DEC - Diff.Enth.Lockout?
BV:29
Dehumid. Disabled Econ.?
BV:30
Dehumidify Input
BV:31
Demand Limit In Effect
BV:32
DEW - OA Dewpt.Lockout?
BV:34
Econ Act. Unavailable?
BV:35
Econ disable in DH mode?
BV:36
Economizer Active?
BV:37
Economizer Control Input
BV:38
Economizer Forced ?
BV:41
Econo Position Override
BV:42
Econ Recovery Hold Off?
BV:44
EDT Sensor Bad ?
BV:45
Emergency Stop
BV:46
Enable Compressor A1
BV:47
Enable Compressor A2
BV:48
Enable Compressor B1
BV:49
Enable Compressor B2
BV:50
Fan Fail Shuts Down Unit
BV:52
Heat Relay 1
BV:53
Heat Relay 2
BV:54
High BP Override
BV:55
Hi Limit Switch Tmp Mode
BV:56
IAQ Pre-Occ Purge Active
BV:57
IAQ Purge
BV:58
LAT Cutoff Mode
See legend on page 182.
APPENDIX E — UPC OPEN CONTROLLER (cont)
NETWORK POINTS LIST (cont)
POINT NAME
READ
DEFAULT
UNITS
ONLY
VALUE
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
W
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
W
n/a
1
R
n/a
n/a
W
n/a
n/a
R
n/a
n/a
W
n/a
n/a
R
n/a
n/a
R
n/a
n/a
W
n/a
n/a
W
n/a
Enable
W
n/a
Enable
W
n/a
Enable
W
n/a
Enable
W
n/a
0
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
R
n/a
n/a
W
n/a
0
R
n/a
n/a
180
BACNET
RANGE
OBJECT NAME
n/a
alm_1
n/a
capmode_1
n/a
igcfan_1
n/a
cmpa1lok_1
n/a
cmpa2lok_1
n/a
cmpb1lok_1
n/a
cmpb2ok_1
n/a
cmpa1_1
n/a
cmpa2_1
n/a
cmpb1_1
n/a
cmpb2_1
n/a
cool_off_1
n/a
modes_1
n/a
sfonstat_1
n/a
dbc_stat_1
n/a
modeadcv_1
n/a
ddbcstat_1
n/a
dec_stat_1
n/a
dhdisabl_1
0-1
dhdiscin_1
n/a
modedmlt_1
n/a
dew_stat_1
n/a
econunav_1
0-1
dhecdisa_1
n/a
ecactive_1
0-1
ecosw_1
n/a
econforc_1
0-1
ecooride_1
n/a
econheld_1
n/a
edt_stat_1
0-1
emstop_1
0-1
cmpa1ena_1
0-1
cmpa2ena_1
0-1
cmpb1ena_1
0-1
cmpb2ena_1
0-1
sfs_shut_1
n/a
hs1_1
n/a
hs2_1
n/a
bphpovrd_1
n/a
limtmode_1
n/a
modeiqpg_1
0-1
iaqpurge_1
n/a
latcmode_1
UNIT
POINT
ALM
CAPMODE
IGCFAN
CMPA1LOK
CMPA2LOK
CMPB1LOK
CMPB2LOK
CMPA1
CMPA2
CMPB1
CMPB2
COOL_OFF
MODES
SFONSTAT
DBC_STAT
MODEADCV
DDBCSTAT
DEC_STAT
DHDISABL
DHDISCIN
MODEDMLT
DEW_STAT
ECONUNAV
DHECDISA
ECACTIVE
ECOSW
ECONFORC
ECOORIDE
ECONHELD
EDT_STAT
EMSTOP
CMPA1ENA
CMPA2ENA
CMPB1ENA
CMPB2ENA
SFS_SHUT
HS1
HS2
BPHPOVRD
LIMTMODE
MODEIQPG
IAQPURGE
LATCMODE