Table 13 — Fan Performance — 50AJ,AK027,030 and 50A2,A3025-030 Units
AIRFLOW
0.2
0.4
(CFM)
Rpm
Bhp
Rpm
4,000
314
0.54
394
5,000
352
0.85
422
6,000
394
1.26
456
7,000
438
1.79
495
8,000
483
2.44
536
9,000
530
3.23
579
10,000
577
4.15
624
11,000
625
5.22
669
12,000
674
6.45
715
13,000
722
7.85
762
14,000
771
9.41
810
15,000
821
11.15
857
AIRFLOW
2.2
2.4
(CFM)
Rpm
Bhp
Rpm
4,000
803
2.22
835
5,000
824
2.72
856
6,000
845
3.31
877
7,000
866
3.99
898
8,000
888
4.77
919
9,000
912
5.65
942
10,000
938
6.65
968
11,000
967
7.78
995
12,000
998
9.07
1025
13,000
1031
10.50
1058
14,000
1067
12.10
1092
15,000
1104
13.88
1128
AIRFLOW
0.2
0.4
(Cfm)
Rpm
Bhp
Rpm
7,000
503
1.96
553
8,000
553
2.62
599
9,000
605
3.39
647
10,000
657
4.29
696
10,500
684
4.80
721
11,000
710
5.33
747
12,000
764
6.52
798
13,000
818
7.85
849
14,000
872
9.33
901
15,000
926 10.98
954 11.37
16,000
980 12.79 1007 13.20 1033 13.60 1058 14.00 1082 14.40 1106 14.79 1130 15.18 1153 15.57 1176 15.96 1199 16.35
17,000
1035 14.77 1060 15.19 1085 15.61 1109 16.03 1132 16.44 1155 16.84 1178 17.25 1200 17.65 1222 18.05 1243 18.46
17,500
1062 15.83 1087 16.25 1111 16.68 1134 17.10 1157 17.52 1180 17.94 1202 18.35 1224 18.76 1245 19.17 1266 19.58
AIRFLOW
2.2
2.4
(Cfm)
Rpm
Bhp
Rpm
7,000
903
4.40
933
8,000
932
5.27
962
9,000
961
6.24
990
10,000
992
7.32 1020
10,500
1008
7.90 1036
11,000
1025
8.52 1052
12,000
1060
9.86 1086 10.19 1112 10.52 1137 10.85 1162 11.17 1187 11.50 1211 11.82 1234 12.15 1257 12.47 1280 12.79
13,000
1097 11.35 1122 11.69 1147 12.03 1171 12.37 1195 12.72 1219 13.06 1242 13.40 1265 13.74 1287 14.08
14,000
1137 12.98 1161 13.34 1184 13.69 1208 14.05 1231 14.41 1253 14.76 1276 15.12 1298 15.47
15,000
1178 14.77 1201 15.15 1223 15.51 1246 15.88 1268 16.25 1289 16.62
16,000
1221 16.73 1243 17.11 1264 17.50 1286 17.88
17,000
1265 18.85 1286 19.25
17,500
1287 19.98
LEGEND
Bhp — Brake Horsepower
edb — Entering Dry Bulb
ewb — Entering Wet Bulb
NOTES:
1. Fan performance is based on wet coils, economizer, roof curb, cabinet
losses, and clean 2-in. filters.
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.6
0.8
Bhp
Rpm
Bhp
Rpm
Bhp
0.72
460
0.89
517
1.05
1.03
484
1.22
540
1.42
1.45
513
1.65
565
1.86
1.98
546
2.19
594
2.41
2.64
583
2.85
628
3.08
3.43
623
3.65
664
3.88
4.36
665
4.58
703
4.82
5.44
708
5.67
744
5.91
6.67
753
6.90
787
7.15
8.07
798
8.30
831
8.55
9.64
844
9.88
875
10.13
11.38
890
11.62
921
11.88
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.6
2.8
Bhp
Rpm
Bhp
Rpm
Bhp
2.38
865
2.55
894
2.72
2.91
887
3.09
916
3.28
3.52
908
3.72
937
3.92
4.21
928
4.43
958
4.66
5.01
950
5.25
979
5.49
5.90
972
6.16
1001
6.42
6.92
997
7.19
1025
7.46
8.07
1023
8.35
1051
8.63
9.35
1052
9.65
1078
9.94
10.80 1083
11.10
1109
11.40
12.41 1117
12.71
1141
13.02
14.19 1152
14.50
1175
14.81
Table 14 — Fan Performance — 50AJ,AKA2,A3035 Units
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.6
0.8
Bhp
Rpm
Bhp
Rpm
Bhp
2.22
601
2.47
646
2.72
2.89
643
3.16
684
3.43
3.68
687
3.97
726
4.26
4.61
733
4.91
769
5.22
5.12
757
5.43
791
5.75
5.66
781
5.99
814
6.31
6.86
830
7.21
861
7.54
8.21
880
8.57
909
8.92
9.71
930 10.09
958 10.45
981 11.76 1008 12.15 1033 12.53 1059 12.91 1083 13.28 1108 13.66 1131 14.03 1155 14.40
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.6
2.8
Bhp
Rpm
Bhp
Rpm
Bhp
4.62
962
4.84
990
5.06 1017
5.52
991
5.77 1019
6.02 1045
6.52 1019
6.79 1047
7.06 1073
7.62 1048
7.91 1075
8.20 1102
8.21 1063
8.51 1090
8.82 1116
8.84 1079
9.15 1105
9.46 1131
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
569
1.22
615
1.39
658
590
1.61
636
1.79
678
613
2.07
658
2.28
700
640
2.64
682
2.86
723
670
3.32
710
3.55
749
704
4.12
741
4.37
778
740
5.06
776
5.32
810
779
6.16
813
6.41
845
820
7.40
851
7.67
882
862
8.81
892
9.08
921
905
10.39
934
10.66
962
949
12.14
977
12.42
1004
3.0
3.2
Rpm
Bhp
Rpm
Bhp
Rpm
923
2.89
950
3.06
976
945
3.46
972
3.65
999
966
4.12
993
4.32
1020
986
4.88
1014
5.10
1041
1007
5.72
1035
5.96
1061
1029
6.67
1056
6.93
1083
1052
7.73
1079
8.00
1105
1077
8.92
1103
9.20
1129
1104
10.24
1130
10.54
1154
1133
11.71
1158
12.01
1182
1165
13.33
1188
13.65
1198
15.13
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
689
2.97
730
3.22
768
724
3.70
763
3.97
799
763
4.55
798
4.83
833
803
5.52
837
5.82
870
825
6.06
857
6.37
889
847
6.63
878
6.95
909
891
7.88
921
8.21
950
938
9.27
966
9.62
993
985 10.82 1012 11.19 1037 11.55 1063 11.91 1088 12.27 1113 12.63
3.0
3.2
Rpm
Bhp
Rpm
Bhp
Rpm
5.27 1043
5.48 1068
6.26 1071
6.50 1097
7.33 1099
7.59 1125
8.49 1127
8.78 1152
9.12 1142
9.41 1166
9.77 1156 10.08 1181 10.39 1205 10.69 1228 10.99 1252 11.29
2. Conversion — Bhp to watts:
Bhp x 746
Watts =
Motor efficiency
3. Variable air volume units will operate down to 70 cfm/ton. Performance at
70 cfm/ton is limited to unloaded operation and may be additionally limited
by edb and ewb conditions.
13
1.4
1.6
1.8
Bhp
Rpm
Bhp
Rpm
Bhp
1.55
697
1.72
734
1.88
1.98
718
2.17
755
2.35
2.49
739
2.70
776
2.90
3.09
761
3.32
798
3.54
3.80
786
4.04
821
4.28
4.62
813
4.88
847
5.13
5.58
843
5.84
876
6.11
6.68
877
6.95
907
7.22
7.93
912
8.21
941
8.49
9.35
950
9.63
977
9.92
10.94
989
11.22
1015
11.51
12.70
1030
12.99
1055
13.28
3.4
3.6
3.8
Bhp
Rpm
Bhp
Rpm
Bhp
3.24
1002
3.41
1027
3.58
3.83
1024
4.02
1049
4.21
4.53
1046
4.73
1071
4.93
5.31
1067
5.53
1092
5.75
6.20
1087
6.43
1113
6.67
7.18
1108
7.43
1134
7.69
8.27
1130
8.54
1155
8.81
9.49
1154
9.77
1178
10.06
10.83
1179
11.13
12.32
1.4
1.6
1.8
Bhp
Rpm
Bhp
Rpm
Bhp
3.46
804
3.70
839
3.94
4.23
834
4.50
868
4.76
5.12
867
5.40
899
5.68
6.12
901
6.42
932
6.72
6.68
920
6.98
950
7.29
7.26
939
7.58
968
7.89
8.54
978
8.87 1006
9.20 1033
9.97 1020 10.31 1046 10.66 1072 11.00
3.4
3.6
3.8
Bhp
Rpm
Bhp
Rpm
Bhp
5.69 1092
5.89 1116
6.09 1139
6.73 1121
6.96 1145
7.19 1168
7.85 1149
8.11 1173
8.37 1196
9.07 1177
9.35 1201
9.63 1224
9.71 1191 10.01 1214 10.30 1238 10.59
2.0
Rpm
Bhp
769
2.05
791
2.54
811
3.11
833
3.77
855
4.52
880
5.39
907
6.38
937
7.50
970
8.78
1005
10.21
1041
11.81
1080
13.58
4.0
Rpm
Bhp
1051
3.76
1074
4.40
1096
5.14
1116
5.97
1137
6.90
1158
7.94
1180
9.08
2.0
Rpm
Bhp
872
4.17
901
5.02
930
5.96
962
7.02
979
7.60
997
8.21
9.53
4.0
Rpm
Bhp
6.28
7.42
8.62
9.91

Hide quick links: