6. Tighten the oil drain plug to specification.
TORQUE
Compressor Oil Drain Plug:
10 ft-lb (14 Nm)
NOTICE
Extract the remaining oil through the discharge-side
connector by rotating the drive pulley
by hand.
7. Measure the drained oil in a measuring cylinder.
8. Check the oil for contamination, dirt, metal shavings,
or varnish color, discard the oil if contaminated.
IMPORTANT
If metal shavings are found in the compressor oil,
replace the compressor assembly.
9. Add new compressor oil through the suction side
r
connector
. Add 150 - 170 cc's of PAG 100 oil.
NOTICE
The suction port on the compressor is marked with an S
and is the larger.
9929399 R01 - 2018-2019 RANGER XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.

ALTERNATOR INSPECTION

1. Disconnect the negative (-) battery cable before
servicing the electrical system.
2. Inspect the electrical harness for cracks, abrasions
and damaged or corroded connectors. ALWAYS keep
the connectors and terminals clean.
3. Start the engine place the Digital Multimeter leads
between the power cable and a clean part of the
e
several times
engine chassis. Ensure the voltage is within
specification.
Loose clothing, hair or other items can be caught in the
compressor drive belt. Take care not to allow loose
items to get caught in the moving compressor drive
ENGINE / COOLING / HVAC SYSTEM
Alternator Output: 14.4 ± 0.3 V
WARNING
belt.
3