AirLink LX60 Series Hardware User Guide
Digital Output/Open Drain
Digital output/open drain, for example to drive an external digital input, is only available
using Pin 4 on the power connector.
Pin 4 (power connector)
Figure 2-17: Digital Output/Open Drain
Table 2-9: Digital Output / Open Drain
Pull-up
Off
Step 8—Check the Router Operation
1. When power is supplied to the AirLink LX60 router, it powers up automatically, as
Rev. 2 June 2021
V
cc
External Pull-Up
Resistor
State
Off
Open Circuit
Active Low
indicated by the flashing LEDs. If it does not turn on, ensure that the:
· Power connector is plugged in and supplying voltage greater than 9 VDC.
Note: Although the LX60 operates in the range 7–36 VDC, low voltage standby mode is
enabled by default. In order to avoid the router powering on in standby mode, ensure that it is
supplied with more than 9 VDC at startup. (You can change the low voltage standby mode
settings once the router is operational. If the Power LED is red, the router is in standby mode.)
· On/Off control (pin 3) is connected to the battery or power source (see
Connect the Power
Protection
Circuitry
Minimum
Typical
on page 16 for details).
30
LX60
V
in
Internal pull-up
resistor
Off
On/Off
Maximum
Comments
5 mA,  5 V
0.5 V
Step 5—
41111782