Environmental Testing

Ingress protection rating is IP20.
Test Method
MIL-STD-810G,
Test method 514.6
MIL-STD-810G,
Test method 516.6,
Procedure 1
MIL-STD-810G,
Test methods
501.5, 502.5
MIL-STD-810G,
Test methods
501.5, 502.5
MIL-STD-810G,
Test method 507.5
IEC 61000-4-2
IEC 60068-2-32
IEC 60068-2-70
Part 2, Test Xb
ISTA 2A 2001,
test categories 1,
4, 5, & 6
Rev. 2 June 2021
Category
Description
Vibration
Frequency range: 5 Hz–500 Hz
Spectrum level: 2.24G on all axes for 8 hours/axis
Operating mode: powered on
Mechanical Shock Half-sine 40G, 15–23 ms,
(+/-X, +/-Y, +/-Z directions, 10 times per axis)
Operating mode: powered on
Temperature
Rugged category: -30 °C to 65 °C
2-hour soak each temp high/low 3 cycles
ramp <= 3 °C/minute
Operating mode: powered on
Temperature
Rugged category: -40 °C to 85 °C
2-hour soak each temp high/low 50 cycles
ramp <= 3 °C/minute
Operating mode: unpowered
Humidity
10 × 48-hour cycles:
Before starting cycles, condition to 23 °C and 50%
relative humidity for 24 hours
2-hour ramp to 60 °C (90% humidity), hold 6 hours
8-hour ramp down to 30 °C (85% to 90% rela-tive
humidity), hold 8 hours
After finishing cycles, condition to 23 °C and 50%
relative humidity for one hour
Operating mode: powered on
Electrostatic
+/-2 kV, +/-4 kV, +/-6 kV, +/-8 kV (Contact and Air)
Discharge
+/-15 kV (Air at antenna connector)
Operating mode: powered on
Free Fall Test
1 m drop height
6 drops onto concrete, 2 per axis: X, Y, Z
Operating mode: unpowered
Marking
The markings are rubbed with water for 10 cycles, then
with lubricating oil for 10 cycles.
Operating mode: unpowered
Package
In shipping packaging.
Cargo vibration and drop test.