Note: During bootup, the I/O settings remain in their default state: the internal pull-up resistor is
disabled, and output current sink switch is open. After bootup, any custom I/O settings are applied.
This may take approximately 30 seconds after the gateway is restarted or powered on.
You can use the I/O pins in conjunction with events reporting to configure the LX60 to
send a report when the state of the monitored router changes, for example when a switch
is opened or closed. For more information, refer to the ALEOS Software Configuration
User Guide (Events Reporting chapter).
Pulse Counter
Pulse counter functionality is available on Pin 4 on the power connector and on Pins 2, 3,
6, and 7 on the auxiliary I/O connector.
You can connect any of these pins to a pulse counter. The digital pulse counter is not
available in Standby mode.
Figure 2-11: Digital Input / Pulse Counter
Maximum frequency: 140 Hz
Duty cycle: 20%–80%
Note: Values may vary, depending on signal noise.
Table 2-4: Pulse Counter
Pull-up
Off
Digital Input
Digital input is available on Pin 4 on the power connector and on Pins 2, 3, 6, and 7 on the
auxiliary I/O connector.
Rev. 2 June 2021
Pin 4 (power connector), or
Digital Pulse
Generator
V
Low
V
High
State
Minimum
Low
High
2.7 V
LX60
V
in
Protection
Circuitry
* Configurable on the ACEmanager I/O tab
Typical
Maximum
1.0 V
V
in
25
Installation and Startup
Internal pull-up
resistor
Off (default)*
Z
in
41111782