Operating Voltage; Power Specifications - Airlink101 LX60 Hardware User's Manual

Table of Contents

Advertisement

Operating Voltage

By default, the router is configured to enter Standby mode at 9 V. If you want to operate
the router at less than 9 volts, power it on using at least 9 V, launch ACEmanager, go to
Services > Power Management and adjust the Standby mode settings.
The maximum ripple voltage to guarantee analog input accuracy must be 100 mVpp.

Power Specifications

Table C-3: Power Supply Specifications
Pin
Name
1
VCC
Table C-4: Ignition Sense Specifications
Pin
Name
3
IS
(Input only)
Note: If you do not connect this pin to the ignition, you MUST connect it to the positive terminal of your power supply or
battery. The device looks for a qualified voltage on this pin as part of the power up sequence. If the device doesn't see it,
the device will not turn on. If you are using a Sierra Wireless AC power adapter, the connection is inside the cable.
Rev. 2 June 2021
Specification
Voltage range
Current Sink
Specification
240 kΩ
Input low state voltage
(maximum)
Input high state voltage
(minimum guaranteed)
43
Parameter
Minimum
VCC
7 V
Parameter
Minimum
V
IL
V
IH
Specifications
Maximum
36 V
Maximum
1.0 V
2.5 V
V
in
41111782