WI818B 5/99
(Direct Entry)
DATA
AUX 1/AUX 2 OPTIONS
ENTRY
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Panic
Key Fob Zone Assignment (refer to display as shown on the previous page: press the (
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point
3; A2 = point 4. Up to 32 key fobs (using 1 button) or 16 key fobs (using 2 buttons) or 8 key fobs (using all 4 buttons) or any
combination up to a maximum of 32 controlled zones can be assigned, providing multiple wireless panic buttons on a
system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone number with
description/location. To assign a key fob to a zone: program the keyfob as you would a transmitter, entering the keyfob's
ID code, check sum and point number at the appropriate zone. The "Quick Method" is not allowed. The zone may be
hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output). NOTE: If assigning
a key fob to a zone, the "ON/OFF" buttons on the key fob will no longer arm/disarm the system. The key fob is converted
to a "panic only" device.
(Direct Entry)
(Direct Entry)
NAPCO Security Systems
Key Fob Transmitters (Press the (
Press the (
"Arm/Disarm" devices (refer to WI752). For each Key Fob Transmitter, enter:
the Key Fob Transmitter number (01–08).
area number to which transmitter is assigned (1 or 2); enter 0 to disable
keyfob.
the 6-digit RF ID # printed on the transmitter (enter all numbers and/or
letters, including leading "0"s, if any).
1-digit checksum number printed on the transmitter (enter all numbers
and/or letters, including leading "0"s, if any).
Aux-1 Option (see key fob aux 1 & aux 2 options).
Aux-2 Option (see key fob aux 1 & aux 2 options).
DATA
AUX 1/AUX 2 OPTIONS
ENTRY
A
Auxiliary
B
Instant
C
Aux. Output Toggle
D
Access on Aux. Output

Enter Date

Press the (
MM/DD/YY, where MM = the month (01–12); DD=the day (01–31); and
YY=the year. Press

Enter Time

Press the (
HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59). Select Am or
Pm by pressing any number button, then press
EXIT DEALER PROGRAM MODE: This completes the custom default program.
Press the
programming or press the
resume normal keypad operation.


) button to set cursor. Keyfobs can be programmed as
Note: If the Key Fob is converted for Two Button "Emergency Use"
(by cutting an internal jumper), both top or bottom buttons must be
depressed to activate an alarms. In this case, the Aux-1 and Aux-2
cannot be programmed.
Press
to save. Press NEXT (

) button to set cursor. Enter the current date in the format
to save. Press NEXT (

) button to set cursor. Enter the current time in the format


button to enter the Direct Address Program Mode for further
button once again to end all programming and
GEM-P3200 Programming Instructions
Page 15
) button to set cursor.)
NOTE: Key fobs 1-8
report as Users 25-32.


) button to proceed.
) button to go backwards.)

) button to proceed.
once again to save.