Area Output Control Options (Addr 2700-2733); Remote Access Logging (Addr 3184); Number Of Relay Board Modules (Addr 3777) - NAPCO GEMINI GEM-P3200 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P3200:
Table of Contents

Advertisement

WI818B 5/99
OUTPUT SILENCED
Pulsed Burg. Output
OUTPUT SILENCED
Pulsed Burg. Output
[Default = blank (•) blank (•) from address 2701-2733]
AREA OUTPUT TURNS OFF UPON DISARM: Select options for any of the 5 Outputs per area when disarming a particular area.
1. Select the desired option by circling
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Enable Keypad 5
1
Enable Keypad 6
2
Enable Keypad 7
4
RESERVED
8
REMOTE ACCESS LOGGING: Enable logging of every keypad access event.
1. Select the desired option by circling
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
3. Enter in address location (left and right digits).
NOTE: Dark shaded data value box shows option not available.
ADDRESS 3777
Number of Relay
LEFT
RIGHT
Board Modules
blank (•)
[Default = blank (•) blank (•)]
NAPCO Security Systems
ADDRESS
2700, 2708, 2716, 2724 & 2732
(TURNED OFF)
LEFT
ADDR
blank (•)
2700
Burglary Output
blank (•)
2708
blank (•)
2716
Fire Output
blank (•)
2724
Reset Relay
blank (•)
2732
Auxiliary Relay
[Default = blank (•) blank (•) from
ADDRESS
2701, 2709, 2717, 2725 & 2733
(TURNED OFF)
LEFT
ADDR
blank (•)
2701
Burglary Output
blank (•)
2709
blank (•)
2717
Fire Output
blank (•)
2725
Reset Relay
blank (•)
2733
Auxiliary Relay
the data values for right digit only (left is not used).
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
the data values for each digit (left and right).
DATA
ENTRIES
Relay Board Module(s)
RIGHT
blank (•)
None
1
1
2
2
3
3
DISARMING AREA 1
RIGHT DATA VALUES (CIRCLE
RIGHT
RSRVD.
RSRVD.
8
4
8
4
8
4
8
4
8
4
DISARMING AREA 2
RIGHT DATA VALUES (CIRCLE
RIGHT
RSRVD.
RSRVD.
8
4
8
4
8
4
8
4
8
4
ADDRESS 3184
RIGHT DIGIT (SUM
OF DATA VALUES)
RELAY BOARD MODULES: Up to 3 External Relay Board
Modules (RM3008) may be programmed.
1. Select the number of relay modules from the table shown.
2. Enter in corresponding right digit address location shown
(left digit is not used).
GEM-P3200 Programming Instructions
)
Area 2
Area 1
Output
Output
Turns Off
Turns Off
2
1
2
1
2
1
2
1
2
1
)
Area 2
Area 1
Output
Output
Turns Off
Turns Off
2
1
2
1
2
1
2
1
2
1
RIGHT DATA
VALUES
SYSTEM OPTIONS
)
(CIRCLE
1
Enable Keypad 1
Enable Keypad 2
2
Enable Keypad 3
4
8
Enable Keypad 4
Page 39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents