Key Fob Transmitters; Dealer Code - NAPCO GEM-P1664EX Programming Instructions Manual

Hide thumbs Also See for GEM-P1664EX:
Table of Contents

Advertisement

WI1387 7/05
KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm
system, each reporting to a central station, a pager or having a description on the keypad that describes the person holding the key
fob, the location where the person holding the key fob is stationed, or the special purpose of the key fob button being depressed.
See Key Fob Transmitters as Zone Input Devices .
Key Fob Transmitters as Arm/Disarm & Control Devices
KFob01
(Press
Keyfobs can be programmed as "Arm/Disarm" devices using their On/Off buttons (refer to WI752). For
Area
each Key Fob Transmitter, enter:
(Direct Entry)
2
000000
if any): "0" through "9" =
(Direct Entry)
2
:0
0
0
(Direct Entry)
For Aux 1/Aux 2 Options: "0", "1", "2" and "9" =
, respectively; "A" =
9
.
G 3
If the Key Fob is converted for Two Button "Emergency Use" (by cutting an internal jumper), both top
or bottom buttons must be depressed to activate an alarm. In this case, the Aux-1 and Aux-2
cannot be programmed. Press
Key Fob Transmitters as Zone Input Devices
(refer to display as shown above: press the PRIOR/NO button to go backwards).
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point 3; A2 =
point 4. Up to 64 key fobs (using 1 button) or 32 key fobs (using 2 buttons) or 16 key fobs (using all 4 buttons) or any combination up
to a maximum of 64 controlled zones can be assigned, providing multiple wireless panic buttons on a system, each reporting to a
Central Station or a pager and/or annunciating on a keypad the key fob zone number with description/location. To assign a key fob to
a zone: program the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at the appropriate
zone. The "Quick Method" is not allowed. The zone may be hardwired to an electrical sensor as well as assigned to a key fob (either
one will activate the zone alarm output). NOTE: If assigning a key fob to a zone, the "ON/OFF" buttons on the key fob will no longer
arm/disarm the system. The key fob is converted to a "panic only" device.
ZONE DESCRIPTIONS: GEM-RP2ASe2 cannot be used to enter Zone Descriptions. To enter Zone Descriptions, you must use the
GEM-RP1CAe2 Keypad / GEM-K1CA Keypad (See WI1386) or the Napco PCD-Windows Quickloader Software.

Dealer Code

D Code
Directly enter the Dealer Code (default = 456789), including leading zeros. Use the
buttons. NOTE: Press
(Direct Entry)
previous code. Press
456789
(Direct Entry)
RE-ENT
(Direct Entry)
L
NAPCO Security Systems
to set cursor).
R
The Key Fob Transmitter number (01–08). Press
Area number to which transmitter is assigned (0 to disable keyfob, 1 - 4). Press
for 0, 1 and 2, respectively.
The 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters, including leading "0"s,
0
; "D" =
; "E" =
G 3
1-digit checksum number printed on the transmitter.
Aux 1 Option (see key fob aux 1 & aux 2 options).
Aux 2 Option (see key fob aux 1 & aux 2 options).
; "B" =
G 0
G 1
U
to save. Press the NEXT/YES button to proceed.
for a zero. Press
0
U
to save. Press the NEXT/YES button to proceed.
01
through
; "A" =
9
G 0
and "F" =
G 4
G 5
,
,
0
1
; "C" =
G 2
U
to save. Re-enter the Dealer Code to verify the
X
GEM-P1664EX Programming Instructions
through
0 8
0
; "B" =
; "C" =
G 1
.
DATA
AUX 1/AUX 2
ENTRY
OPTIONS
0
1
Relay Group 1 Toggle
and
2
2
Relay Group 2 Toggle
and "D" =
9
Keypad Panic
A
Keypad Aux.
B
Instant
C
PGM2 Ouput Toggle
D
Access on PGM2 Output
E
Arm Stay
F
Interior Button
through
1
Page 11
for 01-08.
,
and
1
G
None
9

Advertisement