System Options (Addr 2420-2422 & 4084) - NAPCO GEMINI GEM-P3200 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P3200:
Table of Contents

Advertisement

Page 36
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Disable Keypad
1
Instant Button
Enable
2
Line-Fault Test
Disable AC Fail Detection
4
Telco Fail
8
only when Armed
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Don't Clear Aux. Relay
1
with Arm/Disarm
Telco Answering
2
Service Overide
Disable Auto Status
4
Veri-phone Zones
8
trip Fire Output
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Disable Area Entry Relays
1
Disable Exit/Entry Urgency
2
Tone at Keypad
Enable Burg. Output for
4
Keyfob Chirp
     
8
    
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
RESERVED
1
RESERVED
2
RESERVED
4
Disable Auto
8
Dial Tone Detection
1. Select the desired option by circling
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
3. Enter in address location (left and right digits).
NOTE: Dark shaded data value box shows option not available.
GEM-P3200 Programming Instructions
)
ADDRESS 2420
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
)
ADDRESS 2421
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
*
Note: If "Automatic Interior Bypass" in
Address 2421 is selected, then "Interior 1
Normally Bypassed" in Address 2419 must
also be selected.
)
ADDRESS 2422
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
)
ADDRESS 4084
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
RIGHT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
blank (•)
the data values for each digit (left and right).
WI818B 5/99
RIGHT DATA
SYSTEM OPTIONS
VALUES
)
(CIRCLE
Disable System Trouble
1
Audible at Keypad
Chime on
2
E4 Lug
Disable Code required
4
for Func. Mode Lvl. 1
Disable Code required
8
for Easy Bypass
RIGHT DATA
SYSTEM OPTIONS
VALUES
)
(CIRCLE
Automatic
1
Interior Bypass *
Veri-phone Zones trip
2
Aux. Relay
Veri-phone Zones Priority
4
over Alarms
Enable Output Chirp on
8
Keyfob Arm/Disarm
RIGHT DATA
SYSTEM OPTIONS
VALUES
)
(CIRCLE
1
Fire Output Cadence
Wireless Smoke
2
Low Battery Resound
Supervised
4
Alarm Output
Enable Smoke Detector
8
Dirty Trouble
Note: Right digit is RESERVED
(not used). Enter data in left digit
only.
NAPCO Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents