KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm
system, each reporting to a central station, a pager or having a description on the keypad that describes the person holding the key
fob, the location where the person holding the key fob is stationed, or the special purpose of the key fob button being depressed.
See Key Fob Transmitters as Zone Input Devices .
KFob0 1
Area
(Direct Entry)
00000 0
(Direct Entry)
:0
0
0
(Direct Entry)
, respectively; "A" =
9
.
G3
If the Key Fob is converted for Two Button "Emergency Use" (by cutting an internal jumper), both top
or bottom buttons must be depressed to activate an alarm. In this case, the Aux-1 and Aux-2
cannot be programmed. Press
Key Fob Transmitters as Zone Input Devices
(refer to display as shown above: press the PRIOR/NO button to go backwards).
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point 3; A2 =
point 4. Up to 64 key fobs (using 1 button) or 32 key fobs (using 2 buttons) or 16 key fobs (using all 4 buttons) or any combination up
to a maximum of 64 controlled zones can be assigned, providing multiple wireless panic buttons on a system, each reporting to a
Central Station or a pager and/or annunciating on a keypad the key fob zone number with description/location. To assign a key fob to
a zone: program the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at the appropriate
zone. The "Quick Method" is not allowed. The zone may be hardwired to an electrical sensor as well as assigned to a key fob (either
one will activate the zone alarm output). NOTE: If assigning a key fob to a zone, the "ON/OFF" buttons on the key fob will no longer
arm/disarm the system. The key fob is converted to a "panic only" device.
ZONE DESCRIPTIONS: GEM-DXRP2 cannot be used to enter Zone Descriptions. To enter Zone Descriptions, you must use the
GEM-DXRP1 Keypad / GEM-DXK1 Keypad (See WI1690) or the Napco PCD-Windows Quickloader Software.
D Cod e
(Direct Entry)
45678 9
(Direct Entry)
RE-ENT
(Direct Entry)
NAPCO Security Systems
Key Fob Transmitters as Arm/Disarm & Control Devices
(Press
w
to set cursor).
Keyfobs can be programmed as "Arm/Disarm" devices using their On/Off buttons (refer to WI752). For
each Key Fob Transmitter, enter:
The Key Fob Transmitter number (01–08). Press
Area number to which transmitter is assigned (0 to disable keyfob, 1 - 4). Press
for 0, 1 and 2, respectively.
2
The 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters, including leading "0"s,
if any): "0" through "9" =
0
"D" =
; "E" =
G3
G4
1-digit checksum number printed on the transmitter.
Aux 1 Option (see key fob aux 1 & aux 2 options).
Aux 2 Option (see key fob aux 1 & aux 2 options).
For Aux 1/Aux 2 Options: "0", "1", "2" and "9" =
; "B" =
G0
u
to save. Press NEXT ("r" or

Dealer Code

Directly enter the Dealer Code (default = 456789), including leading zeros. Use the
buttons. NOTE: Press
0
u
previous code. Press
to save. Press NEXT ("r" or
through
; "A" =
9
G0
and "F" =
G5
,
0
; "C" =
G1
G2
p
) to proceed.
u
for a zero. Press
p
LIBRA LIB-P432EX Series Programming Instructions
through
01
08
; "B" =
G1
.
DATA
ENTRY
0
1
,
and
1
2
2
and "D" =
9
A
B
C
D
E
F
to save. Re-enter the Dealer Code to verify the
) to proceed.
Page 11
for 01-08.
,
and
0
1
; "C" =
;
G2
AUX 1/AUX 2
OPTIONS
None
Relay Group 1 Toggle
Relay Group 2 Toggle
Keypad Panic
Keypad Aux.
Instant
PGM2 Ouput Toggle
Access on PGM2 Output
Arm Stay
Interior Button
through
1
9