Static Anchor Procedure - CYBEX Ion Series Assembly Instructions Manual

Pectoral fly / rear deltoid
Table of Contents

Advertisement

Static Anchor Procedure

CAUTION: If it is possible that the length of your bolt will not provide the minimum requirement of 2.5" (63.5mm) of
engagement, a longer anchor should be used.
1. Place unit into position to be mounted and cycle unit to set stance.
2. Each foot must get at least one static fastener.
3. Wearing protective glasses, drill down into the flooring to the required depth as perpendicular as possible, ensuring that the foot
thickness is being accounted for; refer to Anchor Selection and Foot Dimensions.
4. Insert fastener and tighten to 18 Foot-Pounds (24Nm) for 1/4" (6mm) anchor or 40 Foot-Pounds (54Nm) for 3/8" (8mm) anchor.
NOTE: If the legs/frame do not contact the mounting surface DO NOT pull down with the fastener or anchor. Loosen frame
hardware and re-tighten to allow machine to align.
Page 31 of 34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ci-fly

Table of Contents