Install Upgrade Tokens

NOTE: The Motor Control Module, Fluid Control Mod-
ule, and Temperature Control Module connection to the
system is temporarily disabled during the installation of
upgrade tokens.
To install software upgrades:
1. Use correct software token stated in the table. See
Graco Control Architecture
manual for instructions.
NOTE: Upgrade all modules in the system to the
software version on the token, even if you are
replacing only one or two modules. Different soft-
ware versions may not be compatible.
All data in the module (System Settings, USB Logs,
Recipes, Maintenance Counters) may be reset to
factory default settings. Download all settings and
user preferences to a USB before the upgrade, for
ease of restoring them following the upgrade.
See manuals for locations of specific GCA compo-
nents.
The software version history for each system can be
viewed in the technical support section at
www.graco.com.
Token
16G407 Ratio Monitoring (Flow Meters):
- Fluid Control Module
16G365 VRM:
- Advanced Display Module
- Motor Control Module
- Communication Gateway Module
r_257396_3b9905_04b
F
. 11: Remove Access Cover
IG
313873J
Module Programming
Application
ti12334a1
Advanced Display Module
(ADM)
Replace Battery
A lithium battery maintains the ADM clock when power
is not connected.
To replace the battery:
1. Disconnect power to the ADM.
2. Remove rear access panel.
3. Remove the old battery and replace with a new
CR2032 battery.
4. Replace rear access panel.
Install Upgrade Token
See Install Upgrade Tokens on page 47.
Cleaning
Use any alcohol-based household cleaner, such as
glass cleaner, to clean the ADM. Spray on the rag then
wipe ADM. Do not directly spray the ADM.
Maintenance
ti12903a
47