Install Upgrade Tokens; Programming Tokens/Updating System Software - Graco HFR Setup

Nvh foam - cart
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Maintenance

Install Upgrade Tokens

NOTE: The Motor Control Module, Fluid Control Mod-
ule, and Temperature Control Module connection to the
system is temporarily disabled during the installation of
upgrade tokens.
To install software upgrades:
1. Use correct software token stated in the table. See
Graco Control Architecture
manual for instructions.
NOTE: Upgrade all modules in the system to the
software version on the token, even if you are
replacing only one or two modules. Different soft-
ware versions may not be compatible.
All data in the module (System Settings, USB Logs,
Recipes, Maintenance Counters) may be reset to
factory default settings. Download all settings and
user preferences to a USB before the upgrade, for
ease of restoring them following the upgrade.
See manuals for locations of specific GCA compo-
nents.
The software version history for each system can be
viewed in the technical support section at
www.graco.com.
Token
16H821 HFR:
- Advanced Display Module
- Motor Control Module
- High Power Temperature Control Module
- Fluid Control Module (AC Power Pack)
- Discrete Gateway Module
- Communication Gateway Module
16G407 Ratio Monitoring (Flow Meters):
- Fluid Control Module
46
Module Programming
Application
r_257396_3b9905_04b
ti12358a1
F
. 26: Remove Access Cover
IG
Programming Tokens/Updating
System Software
On system software version 1.12.001 (February 2020)
and later, a single 16H821 programming token can be
inserted into the ADM to re-program most of the soft-
ware modules, after power is cycled. To update the
16C014 "MCM Component Blue" software, the 16H821
token must be installed into the MCM module, then
power cycled. Refer to the Advanced Screen 5 on
page 68 in Appendix B - ADM Setup Screens Over-
view for a list of the HFR module software components.
On system software version 1.12.014 and later (Octo-
ber 2020), the capability to program a token using the
HFR ADM module and a USB stick (16 gigabytes or
smaller) is provided. The user must to obtain the latest
16H822 HFR software, and move the file onto the USB
stick in the following directory location:
\GRACO\SOFTWARE\16H822.gti
To program an HFR token and update the software,
perform the following steps:
ti12334a1
ti12354a1
3A2797ZAA

Advertisement

Table of Contents
loading

This manual is also suitable for:

24n57224n576

Table of Contents