Install Vented Oil Cap Before Using Equipment - Graco D60 Operation

Electric supply systems for sealants and adhesives
Hide thumbs Also See for D60:
Table of Contents

Advertisement

4. Insert the power cord through the cord grip and into
the junction box.
Cord Grip
F
. 7: Connect Power
IG
5. Attach the ground wire to the ground terminal inside
the junction box as shown in F
6. Refer to F
. 6 and connect the wires from the
IG
power cord into terminals 2T1 and 6T3.
NOTE: Do not attach the ground wire to the grounding
lug locknut on the outside of the electric driver. Located
below the fan wiring cord grip, the grounding lug locknut
is used for grounding the pump lower. See Grounding
on page 9.
7. Place the fan wires and other power wires into the
open area on either side of the disconnect block
(BD) as space permits.
8. Reinstall the junction box cover and disconnect
switch (K) using the two screws and washers
removed in step 2.
Make sure all wires are routed correctly before instal-
lation. If wires get pinched when the screws are tight-
ened, damage will occur.
3A5379B
For clarity, tan wires and
other power wires not shown
. 7.
IG
NOTICE
9. Tighten the cord grip to securely hold the power
cord in the junction box.
F
. 8: Tighten Cord Grip
IG
Install Vented Oil Cap Before
Using Equipment.
The driver gear-box is shipped from the factory pre-filled
with oil. The temporary unvented cap (PX) prevents oil
leaks during shipment. This temporary cap must be
replaced with the vented oil cap (P), supplied with the
equipment, before use.
NOTE: Prior to use, check oil level. Oil level should be
half way up the sight glass.
ti31010a
F
. 9: Unvented and Vented Oil Caps
IG
Installation