Graco VRM 24F872 Instructions Manual page 79

Hydraulic, plural-component, variable-ratio proportioner
Table of Contents

Advertisement

Error
Code
Error Name Error Description
Red Tank
WMC6
Con. Fault
Blue Tank
WMC5
Con. Fault
Red Inline
WMC3
Con. Fault
Blue Inline
WMC1
Con. Fault
Unexpected current to relay 1
Red Hose
WMC2
Con. Fault
Blue Hose
WMC4
Con. Fault
Red Chiller
WMC7
Con. Fault
Blue Chiller
WMC8
Con. Fault
Motor
A general fault has occurred
WMH1
Controller
within the MCM
Fault
Invalid
The requested controlling
WSC0
Setpoint
value (pressure or flow) is
Request
outside the limits of the system
The shot that was entered for
Invalid Gel
the gel timer is not a valid shot.
WSD0
Timer
This must be fixed before the
Definition
gel timer will function properly
313873J
Error
Type
Cause
Alarm
Alarm
Alarm
Alarm
Shorted module
Alarm
Alarm
Alarm
Alarm
Deviation Internal hardware failure
System incorrectly setup
Deviation
Shot incorrectly defined
Gel timer shot is below
the minimum dispense
amount or set for a
invalid pressure/flow
The MCM has
Deviation
determined that the gel
timer shot will not be able
to be executed based
parameters entered in
the ADM
Appendix D - ADM Event and Error Codes Overview
Solution
If temperature is being affected by a zone that has
been disabled, replace heat module
Cycle power, if the error persists the MCM will need to
be replaced
On the ADM go into the setup screens -> System->
and ensure that all pages have properly defined
values
Redefine shot with control parameters within the limits
of the system
Select a different shot or modify existing shot data
If you are certain that the shot is within parameters,
try running the Learn Mode routine found in the setup
screen Calibration. If the error persists, a gel shot with
reduced control parameters is required.
79