Shutdown

Shutdown

Short-term

1. Place container under mixer.
2. If using a moisture-sensitive material, park pumps.
a. Navigate to the Home screen.
b. Press
repeatedly to select Standby Mode
then press
c. Press
to park pump. Material will dis-
pense. when the pumps are in the parked posi-
tion, they will stop moving.
3. Allow material to drain completely from the mixer
prior to base purge.
4. Perform base purge.
NOTE: A base purge will dispense only the B (Blue)
material to push all mixed material out of the mixer.
Base purge settings are defined on the System #2
screen, see page 61.
a. Press
.
b. Press
to begin dispensing.
c. When all mixed material is pushed out of the
mixer, press
NOTE: Approximately 1 to 2 liters of base material will
need to be dispensed.
5. Press
to park pumps again.
6. Press
.
44
to accept.
to stop dispensing.
7. Place container under the mixer and allow mixer to
drain completely.
NOTICE
Preventing material from draining from the mixer
may cause material in the mixer to harden and
damage the dispense block.
8. Turn Main Power Switch to the OFF position.

End of Shift

1. Perform Short-term Shutdown procedure.
2. Remove, disassemble, and flush mixer.