Graco VRM 24F872 Instructions Manual page 77

Hydraulic, plural-component, variable-ratio proportioner
Table of Contents

Advertisement

Error
Code
Error Name Error Description
No Cooling
T8A7
Red Chiller
No temperature decline
No Cooling
T8B8
Blue Chiller
Red Blanket
T9A6
Temp. Cutoff
Blue Blanket
T9B5
Temp. Cutoff
Heater overtemperature cutoff
Red Inline
T9A3
Temp. Cutoff
Blue Inline
T9B1
Temp. Cutoff
Red Blanket
T9C6
Ctrl
Shutdown
Blue Blanket
T9C5
Ctrl
Shutdown
Red Inline
T9C3
Ctrl
Shutdown
Blue Inline
T9C1
Ctrl
Shutdown
PCB over temperature
Red Hose Ctrl
T9C2
Shutdown
Blue Hose
T9C4
Ctrl
Shutdown
Red Chiller
T9C7
Ctrl
Shutdown
Blue Chiller
T9C8
Ctrl
Shutdown
The voltage to the MCM has
Motor Control
V1H1
dropped to a level where
Undervoltage
performance is greatly affected
Red Blanket
V4A6
Overvoltage
Blue Blanket
V4B5
Overvoltage
Red Inline
V4A3
Overvoltage
Blue Inline
V4B1
Overvoltage
High line voltage
Red Hose
V4A2
Overvoltage
Blue Hose
V4B4
Overvoltage
Red Chiller
V4A7
Overvoltage
Blue Chiller
V4B8
Overvoltage
313873J
Error
Type
Cause
Alarm
Tripped circuit breaker
Defective cooling valve
Alarm
Chilled water supply off
Loose or bad connection Check RTD wiring
Alarm
Defective RTD
Alarm
Defective High Power
Alarm
Temperature Control
Module
Alarm
Loose connections
Alarm
Alarm
Alarm
Alarm
Overheated
Temperature Control
Module
Alarm
Alarm
Alarm
Alarm
Tripped circuit breaker
Alarm
Supply lines providing
low voltage
Alarm
Alarm
Alarm
Alarm
Incoming line voltage is
too high
Alarm
Alarm
Alarm
Alarm
Appendix D - ADM Event and Error Codes Overview
Solution
Visually check circuit breaker for a tripped condition
Disconnect the valve and measure the voltage across
the wires when the chiller is running to ensure 24V is
being delivered to the valve. If so, the cooling valve
will likely need replacing.
Turn on chilled water supply
Replace RTD
Replace High Power Temperature Control Module
Tighten connections
Turn conditioning zone off. Wait a few minutes. If the
condition does not clear or regenerates consistently,
replace heater module
Visually check circuit breaker for a tripped condition
Check incoming voltage to ensure it is above the
minimum operating voltage
Measure voltage across disconnect switch. Voltage
should measure between 190 and 264 Vac.
77