Menus And Submenus - Johnson Controls TEC3010 Installation Instructions Manual

Tec3000 series wireless proportional fan coil and individual zone thermostat controllers with dehumidification capability
Hide thumbs Also See for TEC3010:
Table of Contents

Advertisement

Menus and Submenus

In the following table, the * indicates that the menus depend on your configuration.
Table 10: Menus and Submenus (Part 1 of 8)
Level 1
Level 2
(LCD Screen Name)
Setpoints
Occ Cooling Setpoint
Occ Heating Setpoint
Unocc Cooling Setpoint
Unocc Heating Setpoint
Stby Cooling Setpoint
Stby Heating Setpoint
Dehumidification*
Occ Setpoint Select
Heat Cool Setpoint Mode
Max Heating Setpoint*
Min Heating Setpoint*
Max Cooling Setpoint*
Min Cooling Setpoint*
Max Setpoint*
Min Setpoint*
TEC3000 Series Wireless Proportional Fan Coil and Individual Zone Thermostat Controllers with Dehumidification
Level 3
(Default Values)
72°F (22°C)
68°F (20°C)
80ºF (27°C)
60°F (15°C)
74°F (23°C)
66°F (19°C)
50% RH
Setpoint Offset
Individual
Setpoints
68°F (20°C)
60°F (15°C)
80ºF (27°C)
72°F (22°C)
80ºF (27°C)
60°F (15°C)
Capability Installation Instructions
33
1
Available Values
55 to 85°F (13 to 30°C)
55 to 85°F (13 to 30°C)
55 to 85°F (13 to 30°C)
55 to 85°F (13 to 30°C)
55 to 85°F (13 to 30°C)
55 to 85°F (13 to 30°C)
0 to 100% RH
* Dehumidification Enable = True
Min and Max Setpoint or Setpoint Offset
Common Setpoint or Individual Setpoint
The range (in degrees) from the Min
Heating Setpoint temperature to the Min
Cooling Setpoint temperature minus 1°F
(0.55°C). (The cooling temperature
always needs to be 1°F [0.55°C] above
the heating temperature.)
*These values only appear when Heat
Cool Setpoint Mode == Individual
Setpoints and Occ Setpoint Select ==
Min and Max Setpoint.
45°F (7.22°C) to Max Heating Setpoint
*These values only appear when Heat
Cool Setpoint Mode == Individual
Setpoints and Occ Setpoint Select ==
Min and Max Setpoint.
Min Cooling Setpoint to 100°F (37.77°C)
*These values only appear when Heat
Cool Setpoint Mode == Individual
Setpoints and Occ Setpoint Select ==
Min and Max Setpoint.
The range (in degrees) from the Max
Heating Setpoint temperature plus
1°F (0.55°C) to the Max Cooling Setpoint
temperature.
*These values only appear when Heat
Cool Setpoint Mode == Individual
Setpoints and Occ Setpoint Select ==
Min and Max Setpoint.
Min Setpoint to 100°F (37.77°C)
*These values only appear when Heat
Cool Setpoint Mode == Common
Setpoint and Occ Setpoint Select == Min
and Max Setpoint.
45°F (7.22°C) to Max Setpoint
*These values only appear when Heat
Cool Setpoint Mode == Common
Setpoint and Occ Setpoint Select == Min
and Max Setpoint.