Chapter 9 Operation and Maintenance
Diskette drive A error
Diskette drive B error
Incorrect Drive A - run SETUP
Incorrect Drive B - run SETUP
System Cache Error - Cache disabled
System memory exceeds the CPU's caching
limit
EISA CMOS not writable
DMA Test Failed
Software NMI Failed
Fail-safe Timer NMI Failed
Verify CPU Frequency selection in Setup
System Management Configuration changed
Invalid System Configuration Data
Invalid System Configuration Data - run
configuration utility
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
The system performed an emergency
shutdown.
Manually-operated Retention Latch is not
closed at Hot-Plug PCI slot n
CNR Plug and Play EEPROM contents are
damaged.
CNR version newer than motherboard, some
CNR functionality may be lost.
CNR and AC97 Version do not match, AC97
functionality of CNR ignored.
Illegal AC97 configuration, AC97 Audio and
Modem functions disabled.
Illegal AC97 configuration, AC97 Modem
function disabled.
CNR LAN Interface not compatible with
Motherboard, LAN function disabled.
USB version required by the CNR is not
supported by the motherboard. The CNR USB
functions will operate at lower spe
CNR EEPROM PCI Configuration data size
mismatch
262
table: List of POST error messages
Message
Description
Check the settings of [Diskette A] or [Diskette B] on the"8.2.2
Main Menu" ( pg.226) of the BIOS Setup Utility. Check to see
whether the floppy disk drive cable is connected properly.
Correct the settings of [Diskette A] or [Diskette B] on the"8.2.2
Main Menu" ( pg.226) of the BIOS Setup Utility.
Stop the server once, then restart it again. If the message still
appears, check the error log and replace the CPU if it is at fault.
Or the baseboard must be replaced. Contact an office listed in
the "Contact Information" of the "Start Guide".
Power off the server and turn it back on. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of the "Start Guide".
Power off the server and turn it back on. If the message still
appears, check the error log and replace the CPU if it is at fault.
Or the baseboard must be replaced. Contact an office listed in
the "Contact Information" of the "Start Guide".
If this is displayed right after changing the hardware
configuration, disregard it. If the same message is displayed
again, change the [Reset Configuration Data] setting to [Yes] on
the"8.2.5 Advanced Menu" ( pg.230) of the BIOS Setup
Utility.
Change [Reset Configuration Data] on the"8.2.5 Advanced
Menu" ( pg.230) to [Yes] in the BIOS Setup Utility.
Contact an office listed in the "Contact Information" of the
"Start Guide".
The system shut down due to some reason; refer to the event log
for details.
The latch of the PCI slot is opened. Close the latch.
A CNR error. Power off the server and turn it back on.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".