Installation - Graco Husky 715 Instructions And Parts List

Air-operated diaphragm pumps
Hide thumbs Also See for Husky 715:
Table of Contents

Advertisement

Grounding
WARNING
FIRE AND EXPLOSION HAZARD
This pump must be grounded. Before
operating the pump, ground the system
as explained below. Also read the sec-
tion FIRE OR EXPLOSION HAZARD on
page 3.
To reduce the risk of static sparking, ground the pump
and all other equipment used or located in the pumping
area. Check your local electrical code for detailed
grounding instructions for your area and type of equip-
ment. Ground all of this equipment.
Pump : attach a ground wire (Y) to the grounding
strip (111) with the screw (121), lockwasher (122)
and nut (123), as shown in Fig. 1. Connect the
clamp end of the ground wire to a true earth
ground. Order Part No. 222–011 Ground Wire and
Clamp.

Installation

Y
Fig. 1
Air and fluid hoses : use only electrically conductive
hoses.
Air compressor : follow the manufacturer's recom-
mendations.
Solvent pails used when flushing : follow your local
code. Use only metal pails, which are conductive.
Do not place the pail on a non-conductive surface,
such as paper or cardboard, which interrupts the
grounding continuity.
Fluid supply container: follow your local code.
123
122
111
121
04051B