General Information; Installation - Graco 246611 Instructions And Parts List

High volume plural component pumps
Table of Contents

Advertisement

General Information

NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. If you
supply your own accessories, be sure they are ade-
quately sized and pressure rated for your system.
Figs. 3 and 4 are only guides for selecting and install-
ing system components and accessories. Contact your
Graco distributor for assistance in designing a system
to suit your particular needs.
Prepare the Operator
All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
All operators must thoroughly read all instruction
manuals, tags, and labels before operating the equip-
ment.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE, EXPLOSION, AND
ELECTRIC SHOCK HAZARD on page
4.
1. Pump Model 224567: order Part No. 237569
Ground Wire and Clamp. See Fig. 1. Loosen the
grounding lug locknut (W) and washer (X). Insert
one end of the ground wire (Y) into the slot in lug
(Z) and tighten the locknut securely. Connect the
other end of the wire to a true earth ground.
Y
W
X
Z
Fig. 1

Installation

Pump Models 217337, 246041, and 246611: Re-
move the ground screw (Z) and insert through the
eye of the ring terminal at end of ground wire (Y).
Fasten the ground screw back onto the pump and
tighten securely. Connect the other end of the
ground wire to a true earth ground. See Fig. 2. To
order a ground wire and clamp, order Part No.
222011.
Fig. 2
2. Fluid hoses: use only the Graco heated hose,
which is electrically grounded.
3. Air and hydraulic hoses: use only electrically
conductive hoses.
4. Heater: by wiring to a grounded power supply. In a
mobile installation, be sure the truck or trailer is
grounded to a true earth ground.
5. Hydraulic power supply or air compressor: follow
manufacturer's recommendations.
6. Spray gun: ground through connection to a proper-
ly grounded fluid hose and pump.
7. Fluid supply container: follow your local code.
8. Object being sprayed: follow your local code.
9. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
10. To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.
Y
Z
TI1052
307547
5