TYPICAL INSTALLATION
Key
E
Air Line Filter
F Air Line Lubricator
G Bleed-type Master Air Valve
H
Self-relieving Type Air Regulator
J
Fluid Drain Valve
K
Pump Runaway Valve
L
Fluid Filter
W N
INSTALLATION
The dimensional drawing on page
14 gives the
measurements needed for installing the pump on e
custom designed mounting. See ACCESSORIES on
page
13 for available Graco mounting accessories.
NOTE:
Reference numbers and letters in paren-
theses in the text refer to the Typical Installa-
tion, Fig 1-4, and the Parts Drawing.
Ground the Pump and Other System Components
system, and the object being sprayed
ss
in-
Ground the pump, all other components in the
structed in FIRE AND EXPLOSON HAZARD on
System Aceessorles
Refer to the Typical Installation drawing and the AC-
CESSORIES section on page 13 for assistance in setting
up your system. If you supply your own accessories, be
sure they ere adequately sized to meet your system re-
quirements. Contact
a Graco representative
for
assistance in designing e system to meet your needs.
I n s t a l l an air line filter (E) to remove harmful dirt and
line lubricator (F) for automatic pump lubrication. Install
moisture from your compressed air supply and an air
type air regulator (HI to control pump speed and fluid
a bleed-type master air valve (G), end a self-relieving
pressure.
Install a pump runaway control valve (K) to shut off the
the pre-adjusted setting. A pump which operates too
air supply to the pump if the pump accelerates beyond
fast can be seriously damaged.
-ARNING
Two accessories, the bleed-type master sir valve
(GI,
and the fluid drein valve (J) are required for
your system to reduce the risk of serious bodily in-
jury
from moving parts, fluid injection or splashing
In the eyes or on the skin, when shutting off the
pump.
The
bleed-rype air valve relieves air trapped be-
tween the valve and the pump, after the pump is
shut off. Trepped air can cause the pump to cycle
unexpectedly and result in serious bodily injury if
you are adjusting or repairing the pump.
the displacement pump, hose and gun/dispensing
The fluid
drain velve helps relieve fluid pressure in
valve when shutting off the pump. Triggering the
gun/dispensing valve to relieve pressure may not
be sufficient, especially if there is e clog in the
hose, eun/dispensina valve, or tidnoule.
Connect Hoses
Connect a grounded fluid dispensing hose
(MI
to the
1/2 npt(f) fluid outlet.
Connect a suction hose or siphon
tube to the
3/4 npt(rn) intake (N) of the pump.
hose
(PI
to the pump's 1/2 npt(f) air inlet or the air
Connect e grounded 1/2 in. ID (minimum) air supply
regulator's inlet fitting.
Fill the wet-cup one half full with Graco Throat Seal Li-
quid (TSL) before operating the pump to help prolong
the packing lie. See ACCESSORIES on page 13.
Install a fluid filter (L) and drain vslve (J) on the fluid
dispensing line.