Technical Data - Graco Husky 715 Instructions And Parts List

Air-operated diaphragm pumps
Hide thumbs Also See for Husky 715:
Table of Contents

Advertisement

Maximum Fluid Working Pressure
Air Pressure Operating Range
Maximum Air Consumption
Maximum Free Flow Delivery
Maximum Pump Speed
. . . . . . . . . . . . . . . . . . . . . . . .
Gallons (Liters) per cycle
. . . . . . . . . . . . . . . . . . . . . .
Maximum Suction Lift (water)
Maximum Size Pumpable Solids
Sound power level
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Inlet Size
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Inlet Size.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Outlet Size.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Example of Finding Pump Air Consumption and Air Pressure at a Specific Fluid Delivery and Discharge Head:
To supply 8 gpm (30.3 liters) fluid flow (horizontal scale) at 40 psi (0.28 MPa, 2.8 bar) discharge head pressure (vertical scale) re-
quires 5 scfm (0.14 m /min) air consumption at 70 psi (0.49 MPa, 4.9 bar) air pressure.
feet
psi
(meters)
(MPa, bar)
280
(85.3)
(0.84, 8.4)
240
(73.2)
(0.7, 7.0)
200
(61.0)
(0.56, 5.6)
160
(48.8)
(0.42, 4.2)
120
(36.6)
80
(0.28, 2.8)
(24.4)
40
(0.14, 1.4)
(12.2)
0
TEST CONDITIONS
Pump tested in water with inlet submerged.
PUMPING RATE DECREASE AT DIFFERENT SUCTION LIFTS
EXAMPLE: At a suction lift of 10 ft (3.05 m), the pump flow rate will be decreased by 20 percent.

Technical Data

.
100 psi (0.7 MPa, 7 bar)
. . . . . . . . . . . . . . . .
25–100 psi
(0.18–0.7 MPa, 1.8–7 bar )
. . . . . . . . . . . . . . . . . . . . .
19 scfm
. . . . . . . . . . .
16 gpm (60 l/min)
200 cpm
0.08 (0.3)
. . . . . . . . . . . .
16 ft (4.8 m) dry,
25 ft (7.6 m) wet
. . . . . . . . .
3/32 in. (2.5 mm)
85 dBa
1/4 npt(f)
3/4 npt(f)
3/4 npt(f)
A
E
B
C
D
(7.6)
(15.2)
(1.52)
SUCTION LIFT IN FEET (METERS)
Wetted Parts
. . . . . . . . . . . .
Non-wetted External Parts
Polyester (labels), Polyethylene, Zinc-Plating
Weight
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
* Sound power level measured per ISO standard 9614–2.
PTFE
, Viton , and Hytrel
Santoprene is a registered trademark of the Monsanto Co.
Loctite is a registered trademark of the Loctite Corporation.
INLET AIR PRESSURES
A 100 psi air (0.7 MPa, 7 bar)
B 70 psi air (0.49 MPa, 4.9 bar)
C 40 psi air (0.28 MPa, 2.8 bar)
D 20 psi air (0.14 MPa, 1.4 bar)
AIR CONSUMPTION
E 2 scfm (0.056 m /min)
F 5 scfm (0.14 m /min)
G 10 scfm (0.28 m /min)
H 15 scfm (0.42 m /min)
F
J 20 scfm (0.56 m /min)
G
(22.7)
(30.3)
(37.9)
(45.4)
FLUID FLOW GPM (lpm)
KEY
(3.05)
(4.57)
Vary by Model. See pages 26–30.
. . .
Aluminum, 303 Stainless Steel
Aluminum Pumps: 11 lb (5.0 kg)
Stainless Steel Pumps: 20 lb (9.1 kg)
H
J
(53.0)
(60.6)
(68.1)
FLUID PRESSURE AND FLOW
SCFM AIR CONSUMPTION
(6.1)
(7.62)

Advertisement

Table of Contents
loading

Table of Contents