Reassembly
1. If the detent collar (7) was removed, carefully
install a new collar in a new cover (2). Using a
rubber mallet, carefully press fit the detent collar
(7) into the cover (2). See Fig. 13.
2. Grease the detent spring (6) and place it in the
collar (7). Grease the ball (8) and set it on the
spring.
3. Grease the o-ring (20) and install it in the hole (H)
in the cover (2). See Fig. 13. Slide the washer (18)
onto the blunt end of the reset shaft (21). Insert
the shaft through the cover (2) until it seats.
Apply grease (25).
Press fit.
8
6
7
Fig. 13
4. Grease the spring (3). Place the link stop (4) inside
the spring. See Fig. 14.
Service
21
18
H
20
2
5. Grease the detent link (22) and link spacer (17).
Assemble the detent link, link spacer, and actuator
link (16) as shown in Fig. 14. The raised bumps on
the links (16 and 22) must face up.
6. Squeeze the spring (3) and install it and the stop
(4) in the link assembly. The spring tension will
hold all these parts together. Grease the valve cup
(5) and install it in the link assembly as shown.
7. Install the link assembly onto the air valve cover
(2) so the pointed end of the reset shaft (21) fits
through the holes in the links and the square part
of the shaft engages the square hole in the detent
link (22). Make certain the bumps on the detent
link (22) engage the detent ball (8).
Apply grease (25 ).
Bumps face up.
Reset shaft square must
engage with square hole.
16
17
22
Fig. 14
5
4
8
3
2
7505A