Installation - Graco 236-463 Instructions-Parts List Manual

Pumps with severe-duty rod and cylinder
Table of Contents

Advertisement

General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. Refer to
the Product Data Sheet, Form No. 305–724. If you
supply your own accessories, be sure they are ade-
quately sized and pressure rated for your system.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 5.
1. Pump: use a ground wire and clamp. See Fig. 1.
Loosen the grounding lug locknut (W) and washer
(X). Insert one end of a 1.5 mm (12 ga) minimum
ground wire (Y) into the slot in lug (Z) and tighten
the locknut securely. Connect the other end of the
wire to a true earth ground. Order Part No.
237–569 Ground Wire and Clamp.
W
Y
Fig. 1
2. Air and fluid hoses: use only electrically conductive
hoses.

Installation

3. Air compressor: follow manufacturer's recommen-
dations.
4. Spray gun: ground through connection to a prop-
erly grounded fluid hose and pump.
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
7. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
8. T o maintain grounding continuity when flushing or
relieving pressure , hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.
System Accessories
Fig. 2 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Air and Fluid Hoses
Be sure all air hoses (H) and fluid hoses (N and P) are
properly sized and pressure-rated for your system.
Use only electrically conductive hoses. Fluid hoses
X
must have spring guards on both ends. Use a whip
hose (P) and a swivel (R) between the main fluid hose
(N) and the gun (S) to allow freer gun movement.
Z
Mounting Accessories
Mount the pump (A) to suit the type of installation
planned. Fig. 2 illustrates a wall mount system. Pump
dimensions and the mounting hole layout are shown
on page 27.
If you are using a floor stand, refer to its separate
manual for installation and operation instructions.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dura-flo 600237-369

Table of Contents