Installation - Graco Husky 1040 D71 Instructions-Parts List Manual

Acetal, polypropylene, and pvdf air-operated diaphragm pumps
Table of Contents

Advertisement

General Information
D The Typical Installation shown in Fig. 2 is only a
guide for selecting and installing system compo-
nents. Contact your Graco distributor for assistance
in planning a system to suit your needs.
D Always use Genuine Graco Parts and Accessories.
D Reference numbers and letters in parentheses refer
to the callouts in the figures and the parts lists on
pages 26 to 27.
WARNING
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can
cause serious injury or death if splashed
in the eyes or on the skin, inhaled, or
swallowed.
D Read TOXIC FLUID HAZARD on page 3.
D Use fluids and solvents that are compatible with
the equipment wetted parts. Refer to the Tech-
nical Data section of all equipment manuals.
Read the fluid and solvent manufacturer's
warnings.
4
308443

Installation

Tightening Screws Before First Use
Before using the pump for the first time, check and
retorque all external fasteners. See Torque Se-
quence, page 30. After the first day of operation,
retorque the fasteners. Although pump use varies, a
general guideline is to retorque fasteners every two
months.