Tools Required; Replacing The Air Valve - Graco Husky 715 Instructions And Parts List

Air-operated diaphragm pumps
Hide thumbs Also See for Husky 715:
Table of Contents

Advertisement

Tools Required

Torque wrench
Phillips screwdriver
O-ring pick
1/8" EZY-OUT bearing extractor
Rubber mallet

Replacing the Air Valve

NOTE: Air Valve Kit 239–952 is available. Parts
included in the kit are marked with a symbol, for exam-
ple (2 ). A tube of general purpose grease (25 ) is
supplied in the kit. Install the kit as follows.
21
A
10
Fig. 8
Service
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 10.
1. Relieve the pressure.
2. Unscrew the six mounting screws (10) and remove
Torque oppositely and evenly to 20–25 in-lb (2.3–2.8 N.m).
Apply grease (25 ).
19
WARNING
the air valve (A) from the pump. See Fig. 8.
GREASE APPLICATION
16
14
21

Advertisement

Table of Contents
loading