Rackmount Installation

3.8
RACKMOUNT INSTALLATION
To install the switch in a 19-inch rack, an accessory kit containing the rackmount brackets, and
mounting screws to attach the rackmount brackets are shipped with the switch.
Guidelines for Rackmount Installation
The installation site must be within reach of the network cabling and meet the requirements listed
below:
Appropriate grounded power receptacles must be located within seven feet of the location.
A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation
site with fluctuations of less than 10°C (18°F) per hour.
Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance
space of 5.1 cm (2.0 in.) at the left, right, and rear of the device.
Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje
un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y a la parte posterior del
aparato.
Warning: Before installing the chassis into a rack, ensure that the rack can support the device(s)
without compromising the stability of the rack. Otherwise, personal injury and/or equipment
damage may result.
Advertencia: Antes de instalar el chassis en un rack, asegurarse que el rack puede soportar
el(los) dispositivo(s) sin comprometer la estabilidad del mismo. De otra forma puede suceder
algun tipo de daño personal o del equipo.
Warnhinweis: Schützen Sie sich vor Verletzungen und Geräteschaden, überzeugen Sie sich vor
der Installation des Chassis in das Rack, von dessen Stabilität.
3-10
Hardware Installation